Expansion I/O ports

The four RJ45 connectors on the rear panel are used

to interconnect LecNet2™ units together. These ports

are only used to transfer digital audio information via

the Digital Audio Network Interface (DANI) between the

units.

WARNING: The Expansion I/O connectors are

NOT EtherNet, CobraNet or any other network

based device interconnects. Connecting them

to Ethernet, CobraNet or other network based

device may cause damage to either unit.

In a stacked configuration, one unit must be configured

as the Master unit and the others as Slave units. Con-

figuring a unit as a Master or a Slave can be done using

the Control Panel GUI interface.

Note: In order to use the convenient Control Panel

GUI, LecNet2™ must be installed on the attached

computer system. (See

Installing LecNet2™

Software and USB Driver.)

To connect the Master/Slave units, plug one end of a 12

inch Cat5e cable (two are supplied with each with unit)

to the transmit (TX) port on the Master unit, and con-

nect the other end to the corresponding receiver (RX)

port on the Slave unit immediately below the Master.

Repeat this procedure with the second Cat5e cable.

(See

Expansion Port Digital Audio Network Interface

Interconnection Diagram.)

CAUTION: Do not connect these ports to each

other on a single unit, and to not cross the

cables between the units.

Master/Slave Configuration

When stacking multiple units, one unit is always set as

the Master and all subsequent units are set as Slaves.

The Control Panel GUI interface is used to do this.

DM84 Rear Panel

LecNet 2

Expansion I/O Ports

Programmable

Inputs and Outputs

PROGRAMMABLE INPUTS/OUTPUTS

1 - GND

2 - IN 1

3 - IN 3

4 - IN 5

5 - IN 7

6 - IN 9

7 - IN 11

8 - GND

9 - OUT 1

10 - OUT 3

11- OUT 5

12 - OUT 7

13 - GND

14 - +5V

15 - IN 2

16 - IN 4

17 - IN 6

18 - IN 8

19 - IN 10

20 - +5V

21 - OUT 2

22 - OUT 4

23 - OUT 6

24 - OUT 8

25 +5V

1

13

ccw

cw

ccw

cw

ON

OFF

OUT 3

OUT 4

OUT 1

IN 1

IN 2

IN 3

500 Ohms

500 Ohms

500 Ohms

LED

LED

LED

Potentiometer

Potentiometer

Switch

Three Programmable Inputs:

2 - 10 K linear potentiometers

for volume control

1 - Tobble switch for muting

3 Programmable Outputs:

LEDS for function indicators

(380 to 500 Ohm resistors in-line

to avoid burning out LEDS)

NOTE

Common Connections can be used for

all voltage and ground connections

among all devices.