12.2 Output Zone/Channel Connections Table—For Trinity Multi

-zone


Either 9, or 12 output channel options are available for driving and
dimming LEDs. Channels are assigned to zones as shown in the following
tables. A 9 channel option will provide 9 zones for dimming and a 12
channel option will provide 12 zones for dimming.

Zone Number

Output Channel

Belden/Alpha or Equivalent Wire Color/

Polarity

1

1

WHT + / BLK -

2

2

RED

+ / BLK -

3

3

GREEN

+ / BLK -

4

4

WHT + / BLK -

5

5

RED

+ / BLK -

6

6

GREEN

+ / BLK -

7

7

WHT + / BLK -

8

8

RED

+ / BLK -

9

9

GREEN

+ / BLK -

10

10

WHT + / BLK -

11

11

RED

+ / BLK -

12

12

GREEN

+ / BLK -

9/12 Channel - Zone Connection Table

12.3 Multi-zone Analog Interface Specification and Cabling

Connections

Trinity Multi-zone Analog uses the same interface and cabling
specifications as Trinity Analog. See sections 11.3 and 11.4 for
requirements.

Document: 66APPMAN Rev: H

3 of 32

1.0 MECHANICAL DIMENSIONS

1.00
25.4

1.70
43.2

2.17

55

3.30
83.8

DC OUTPUT

1/2" CONDUIT KNOCKOUT BOTH SIDES

DIMENSIONS: INCHES

[MM]

AC INPUT

16.91
429.5

18.63
473.1

4.76

120.9

6.0

152.4