Document: 66APPMAN Rev: H

26 of 32

Note: This wiring configuration provides simultaneous dimming control
for all zones 1,2,3,4 with a commercial dimming interface comprising (1)
0-10Vdc control signal.

11.6 INSTALLATION EXAMPLES

(1) TRINITY ANALOG, (1) COMMERCIAL DIMMING PANEL
WITH (1)

Document: 66APPMAN Rev: H

7 of 32

Table 10

TRINITY Multi-Zone Analog Model Options

Model #

# of

Channels

Drive

Current

Output Voltage

Range (under

load Conditions)

Maximum # of

LEDs per

Channel

(typical)

70-12-0350-12Z-PI

12

350 mA

12 to 47 Vdc

4 to 12

70-09-0500-12Z-PI

9

500 mA

12 to 47 Vdc

4 to 12

66-12-0700-12Z-PI

12

700 mA

6 to 27 Vdc

2 to 8

66-09-1000-12Z-PI

9

1000mA

6 to 27 Vdc

2 to 8

Table 11

Multi-Zone Analog Interface Specifications

Control Method

Analog 0-10Vdc
IEC 60929 Annex E Out-
puts 0.5mA maximum
Or
Variable 0-10Vdc Voltage
Source

Class 2 outputs

Master Control:
Simultaneous control of all
output channels

Zonal Control:
Independent control of up to 12
channels

Loss of Analog
Input Signal

Outputs will go to 100% light intensity in less than 1 second

Connection Method

UL recognized cage clamp connector
14 AWG to 28 AWG wiring

Electrical Isolation

Master, Zone 1 to Zone 12 outputs
electrically isolated from earth ground