The robot does not move at power on, The picker partially grips a tape cartridge, The barcode reader fails – HP ESL E-series Tape Libraries User Manual

Page 75: The robot times out or hangs, The robot fails during an operation, The robot drops a cartridge, 75 the picker partially grips a tape cartridge, 75 the barcode reader fails, 75 the robot times out or hangs, 75 the robot fails during an operation

Advertising
background image

The robot does not move at power on

Make sure all internal packing materials (foam pads, tie wraps, and shipping restraints) have
been removed.

Check the Stop button; make sure the library is on-line and not in the “stopped” mode.

The picker partially grips a tape cartridge

Issue a Move Cartridge command using your application software to move the cartridge from the
picker to an empty storage bin.

If the problem continues, contact a field service engineer.

The barcode reader fails

Verify that nothing obstructs the reader.

Make sure that approved bar-code labels are being used and are correctly applied.

Then, restart the library. If the problem continues, contact your service provider.

The robot times out or hangs

Verify that nothing obstructs the robot.

Recalibrate the library.

Retry the operation. If it still fails, contact a field service engineer.

The robot fails during an operation

Write down the details of the error message, including the SK, ASC, and ASCQ numeric values.
Look up the code and try the suggested recovery procedures.

Press OK to clear the message.

The robot drops a cartridge

Open the doors. Retrieve the cartridge, orient it properly, and place the cartridge in an empty
storage bin. (Do not try to place the cartridge in the picker.)

Perform an inventory.

NOTE:

If the operator manually places a cartridge in an empty bin, he must then run an inventory so the
library records the position of the manually-placed cartridge.

A cartridge is in the picker at start-up, when a move command is requested, or
after a place command is executed

If possible, initiate a Move Cartridge command from the picker to a storage slot using your applic-
ation software.

If the problem continues, contact a field service engineer.

HP StorageWorks ESL E-Series Tape Library

75

Advertising