Lenovo ThinkServer RD550 User Manual

Page 136

Advertising
background image

Attention: An unoccupied drive bay without any other protection might impact the EMI integrity and cooling
of the server, which might result in overheating or component damage. To maintain the EMI integrity and
cooling of the server, install a new hot-swap hard disk drive or solid-state drive as soon as you remove the
failing one or the dummy tray.

Before you begin, review the following solid-state drive installation rules:

• Follow the order of the hard-disk-drive bays when installing a solid-state drive. See “Server components”

on page 25 to locate the hard-disk-drive bays in your server.

• For RAID configuration, the solid-state drives must be the same type with the same capacity if they are

within a single RAID array. For more information, see “Configuring RAID” on page 56.

• For solid-state drives with different capacities, install the solid-state drive by following the order of the

hard-disk-drive bays as well as the order from the lowest capacity to the highest capacity.

Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.

Notes:

• Depending on the model, your server might come with 3.5-inch hot-swap hard disk drives or 2.5-inch

hot-swap hard disk drives. The illustrations in this topic are based on server models with 3.5-inch
hot-swap hard disk drives. For other models, the replacement procedure is similar.

• Depending on the model, your server might look slightly different from the illustrations in this topic.

• Use any documentation that comes with the solid-state drive and follow those instructions in addition to

the instructions in this topic.

Installing a 2.5-inch solid-state drive into a 3.5-inch hard-disk-drive bay

Attention: Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii
and “Guidelines” on page 61.

Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.

Note: Ensure that you have a 3.5-inch to 2.5-inch drive adapter and a 3.5-inch drive bracket available
before the installation.

To install a 2.5-inch solid-state drive into a 3.5-inch hard-disk-drive bay, do the following:

1. Locate the appropriate hard-disk-drive bay. See “Front view of the server” on page 17.

2. Press the release button

1

to open the handle of the dummy hard-disk-drive tray.

1

Figure 95. Opening the handle of the dummy hard-disk-drive tray

122

ThinkServer RD550 User Guide and Hardware Maintenance Manual

Advertising