Hot-swap-drive status LEDs

Each hot-swap drive has two status LEDs on the front.

1

2

Figure 28. Hot-swap-drive status LEDs

1

Drive activity LED

2

Drive status LED

Description

Off

Off

The drive has failed or is not present.

On, green

Off

The drive is present but not in use.

Blinking, green

Off

The drive is active and data is being
transferred.

On, green

Blinking rapidly (about four flashes
per second), amber

The RAID controller is identifying the
drive.

On, green

On, amber

The RAID array has failed and cannot
be recovered. You need to recreate a
new array.

Blinking, green

Blinking slowly (about one flash per
second), amber

The drive is being rebuilt.