23. Install the heat sinks on the new system board. See “Installing or replacing a heat sink” on page 104.

24. Reinstall all parts that you have removed one by one in the reversed sequence as you remove them.

Connect all cables to the new system board. Refer to the information that you have noted down and the
related topics in “Installing, removing, or replacing hardware” on page 64.

25. If you are instructed to return the old system board, follow all packaging instructions and use any

packaging materials that are supplied to you for shipping.

The old system board must be returned with two microprocessor socket covers to protect the pins on the
microprocessor sockets during shipping and handling. Use the microprocessor socket covers removed
from the new system board.

To install a microprocessor socket cover on the old system board, do the following:

1. Close the microprocessor retainer. Close the small handle

1

first and then close the small handle

2

. Ensure that the retainer is locked into position and the new microprocessor is securely seated in

the socket.

Note: There are two marks on the microprocessor retainer. Ensure that you close the small handle
marked with

first and then close the small handle marked with

. Always follow the correct sequence

when you close the small handles.

Figure 124. Securing the microprocessor retainer

Chapter 6

.

Replacing hardware

143