Power supply status leds, Connecting cables – Lenovo ThinkServer RD550 User Manual

Page 59

Advertising
background image

Power supply status LEDs

Each hot-swap power supply has three status LEDs.

1

2

3

Figure 29. Power supply status LEDs

LED

Status

Description

Action

Off

The power supply is
disconnected from the ac
power source.

No action is needed.

1

Input status LED

On, green

The power supply is connected
to the ac power source.

No action is needed.

Off

The server is off or the power
supply is not working normally.

Replace the power supply.
See “Installing or replacing a
hot-swap redundant power
supply” on page 116.

Blinking, green (about 1
flash every 2 seconds)

The power supply is in cold
redundancy active mode.

No action is needed.

Blinking, green (about 2
flashes per second)

The power supply is in cold
redundancy sleep mode.

No action is needed.

2

Output status

LED

On, green

The server is on and the power
supply is working normally.

No action is needed.

Off

The power supply is working
normally.

No action is needed.

3

Fault LED

On, amber

The power supply has failed.

Replace the power supply.
See “Installing or replacing a
hot-swap redundant power
supply” on page 116.

Connecting cables

To connect the signal cables from the installed hardware components, refer to the related information
in the following topics:

“System board components” on page 37

“AnyRAID adapter, RAID adapter, and pass-through board” on page 28

“Hot-swap-drive backplane” on page 34