2 preventive maintenance – Lukas Concrete crushers User Manual

Page 27

Advertising
background image

27

10.2 Preventive maintenance

10.2.1 Care instructions

The exterior of the equipment must be cleaned from time to time in order to protect it from

external corrosion. Oil must be applied to the metallic surfaces.

10.2.2

Routine checks

Regularly check the torque of the pivot bolt.

For torques, see Chapter “Technical Data”.

Check the cutting faces and repair if possible. Refer to the Chapter “Regrinding the Crusher Arms”.

Once a day when the unit is being used, the pivot pin should be greased with LUKAS special

grease.

The grease nipple (item A) is located immediately

on the central pivot pin on the side with the locknut

(item B).

Grease the cutting unit with a grease gun as shown

on the right using LUKAS special grease.

Excess grease that remains on the grease nipple

after greasing (see left) should be removed and

disposed of properly.

A

B

CAUTION!

Particularly when working with the crusher arms pointing upwards, make sure that

no larger broken off pieces make their way under the flexible protective sleeve into

the mechanical section of the unit. The moving parts of the unit can be blocked and

even destroyed by this.

The unit must therefore be checked for dirt contamination and foreign bodies in the

mechanical section and cleaned if necessary after each time it is used in this way.

Advertising