290

[Input X] Click the Arrow buttons to select an Input to set up.

Figure 6-2


„

Name: Specifies a name for the input device in the Name field.

„

Signal Type: Select a signal type for your input device: NO (normally open), NC (normally close)

or Latch Trigger. Clicking the finger button can apply your selection to all input devices.

For details on Latch Trigger, see Latch Trigger later in this chapter.

`[Output X] Click the Arrow buttons to select an output.

Figure 6-3

„

Name: Specifies a name for the output device in the Name field.

„

Force Output: Click to test signal to the selected device.

„

Signal Type: There are six signal types available: N/O (Normal Open), N/O Toggle, N/O Pulse,

N/C (Normal Closed), N/C Toggle, and N/C Pulse. Choose the one that mostly suits the device

you’re using. For Toggle output type, the output continues to be triggered until a new input trigger

ends the output. For Pulse output type, the output is triggered for the amount of time you specify

in Sec field.

„

Keep Last Toggle Status: See Keeping Last Toggle Status later in this chapter.

Note: PTZ camera and I/O devices cannot be assigned to the same port at the same time.