- 397 -

11. Now assign the Floor Map; selecting which floors this controller will be servicing.

12. Save these settings. The software generates an alert stating the controller needs to

be reset. Click Yes to allow the reset.

13. Verify the outputs on the controller are configured correctly by expanding one of

the buses then expanding the Outputs. Select an output and in its properties you
should see it configured as an ‘Elevator Output.’ The associated reader should be
the reader wired into bus 1.

14. Next is adding the 4x4 modules or GIOX unit(s); these should already be wired into

each of the RS-485 buses of the NXT controller.

15. Highlight each of the buses from within the hardware tree and click ‘Add 4x4-

MSC.’ or 'Add GIOX-MSC.' The controller should start polling the 4x4(s) or GIOX
immediately and they will appear beneath the reader(s) as shown below. If you are
using a GIOX, the input/output configuration of the unit will be detected and dis-
played within a confirmation box detailing how many input or output cards are con-
nected.