Ethernet (Art-Net) Comm

The starting address for Ethernet (Art-Net) systems can be set from the HOME screen.

To program a starting address:

Step

1. At Home screen, press address number panel.

Step

2. At numeric keypad, enter new starting address and press ENTER.

Figure 2-16: Setting Starting Address (Ethernet Control)

To select an Art-Net universe:

If using Ethernet control, a universe must be selected in addition to the DMX address. The universe can be selected
and displayed in either alphabetic or numeric mode (using the UNIV FORMAT screen). The alpha mode is useful to
differentiate universes from DMX addresses and is the standard on PRG console systems. In alpha mode, the valid
universes are A-IV, selected from the alphabetic keypad (as shown below). If in numeric mode, the valid universes are
0-255, selected from the numeric keypad.

To set the Universe and Universe Format, press the CONFIG panel at the Home screen:

Figure 2-17: Selecting a Universe (Ethernet Control)

Note: Refer to

"Menu System"

on page 30 for more information about the Menu Touchscreen.

Control Input Type (Ethernet)