Toa HX-7W-WP User Manual

Page 16

Advertising
background image

16

• Filter characteristics when used with the FB-150 series Subwoofer System

Note

When using the processor with the HX-7 Series and the FB-150 Series, ensure that the wiring polarity of both

units is the same.

[When using the 0º mode]

Filter

Frequency

Gain

Q

Delay

HX-7 Series

HPF (12 dB)

90 Hz

-

0.700

0 ms

PEQ

160 Hz

3.0

1.011

PEQ

1.75 kHz

-3.5

3.633

PEQ

4.62 kHz

-7.0

2.145

PEQ

9.25 kHz

-7.5

1.414

FB-150 Series

HPF (12 dB)

30 Hz

-

1.000

0 ms

PEQ

40 Hz

3.0

1.414

LPF (12 dB)

100 Hz

-

1.000

[When using the 15º mode]

Filter

Frequency

Gain

Q

Delay

HX-7 Series

HPF (12 dB)

90 Hz

-

0.700

0 ms

PEQ

160 Hz

3.0

1.011

PEQ

1.75 kHz

-3.0

3.633

PEQ

4.62 kHz

-7.5

2.145

FB-150 Series

HPF (12 dB)

30 Hz

-

1.000

0 ms

PEQ

40 Hz

3.0

1.414

LPF (12 dB)

100 Hz

-

1.000

[When using the 30º mode]

Filter

Frequency

Gain

Q

Delay

HX-7 Series

HPF (12 dB)

90 Hz

-

0.700

0 ms

PEQ

160 Hz

3.0

1.011

PEQ

1.75 kHz

-2.0

3.633

PEQ

5.00 kHz

-3.5

1.414

FB-150 Series

HPF (12 dB)

30 Hz

-

1.000

0 ms

PEQ

40 Hz

3.0

1.414

LPF (12 dB)

100 Hz

-

1.000

[When using the 45º mode]

Filter

Frequency

Gain

Q

Delay

HX-7 Series

HPF (12 dB)

90 Hz

-

0.700

0 ms

PEQ

160 Hz

3.0

1.011

PEQ

1.75 kHz

-2.5

3.633

PEQ

4.62 kHz

-2.5

2.456

FB-150 Series

HPF (12 dB)

30 Hz

-

1.000

0 ms

PEQ

40 Hz

3.0

1.414

LPF (12 dB)

100 Hz

-

1.000

[When using the 60º mode]

Filter

Frequency

Gain

Q

Delay

HX-7 Series

HPF (12 dB)

90 Hz

-

0.700

0 ms

PEQ

160 Hz

3.0

1.011

PEQ

5.30 kHz

-3.0

2.456

FB-150 Series

HPF (12 dB)

30 Hz

-

1.000

0 ms

PEQ

40 Hz

3.0

1.414

LPF (12 dB)

100 Hz

-

1.000

Advertising