6 ethernet interfaces, Ethernet interfaces, Ethernet interfaces connectors – Dialogic SS7G21 User Manual

Page 38: Section 6.6

Advertising
background image

38

Chapter 6 Interfaces

An SS7 Serial Interface Port Splitter Cable is available, DKL26 (see

Chapter 12, “Part Number Reference”

).

This is a cable that converts from the dual V.11 26-way high density D connector (detailed in

Table 6

) to two

15-way male DB15 connectors (detailed in

Table 7

). When installing this cable, ensure that the ferrite clamp

is fitted close to the 26-way connector.

6.6

Ethernet Interfaces

To ensure EMC product regulation compliance for intra-building lightning surges, the product shall only be
used with shielded LAN cables that are grounded at both ends.

Two pairs of Ethernet connectors are provided on the SS7G21 and SS7G22. ENET 1 and ENET 2 are provided
by the Server Board, and ENET LNK A and ENET LNK B are provided by a separate low-profile PCI NIC.

Figure 9

shows the Ethernet connectors provided by the PCI NIC and the Server Board.

The Ethernet interface connectors incorporate status LED indicators. The LEDs on the network interface
connectors indicate link/activity on the network and the speed of operation. The green LED, when on,
indicates network connection and when blinking indicates TX/RX activity. The speed LED indicates 1000
Mbps when amber, 100 Mbps when green, and 10 Mbps when off.

Table 8

shows the Ethernet connector

pinouts.

A NIC Activity LED (green) on the front panel provides an indication of activity on the ENET 1 or ENET 2
ports. See

Section 5.2, “Front Panel” on page 32

for more information.

Figure 9. Ethernet Interfaces Connectors

Table 7. SS7 Serial Interface Port Splitter Cable 15-Way Male DB15 Connector Pinouts

Pin No

Direction

Function

1

Chassis ground

2

Output

V.11 Transmit true data

3

No connection

4

Input

V.11 Receive true data

5

No connection

6

Input

V.11 Receive true clock

7

Output

V.11 Transmit true clock

8

Signal Ground

9

Output

V.11 Transmit inverted data

10

No connection

11

Input

V.11 Receive inverted data

12

No connection

13

Input

V.11 Receive inverted clock

14

Output

V.11 Transmit inverted clock

15

No connection

Pin 1

Link/Activity

Indicator

(Green)

Speed

Indicator

(Multi-colored)

ENET 2 (top) and ENET 1 (bottom)

Provied by the Server Board

Pin 1

ENET LNK B (left) and ENET LNK A (right)

Provided by the NIC

Link/Activity

Indicator

(Green)

Speed

Indicator

(Multi-colored)

Pin 1

Advertising
This manual is related to the following products: