A.1.2.2 connecting an spci2s to a nortel dms100, A.1.2.3 connecting an spci2s to an inet tester – Dialogic SS7G21 User Manual

Page 84

Advertising
background image

84

Appendix A

A.1.2.1

Connecting an SPCI2S to an M34 Block Connector

The following table provides information on connecting an SPCI2S (working as a DTE) to a V.35 block
connector (working as a DCE).

Also, it may be necessary to connect:

M34 pin E (DCERDY-P/DSR) to M34 pin H (DTERDY-P/DTR) and

M34 pin C (RTS-S) to pin D (CTS-P)

A.1.2.2

Connecting an SPCI2S to a Nortel DMS100

The following information has also been used in conjunction with a Nortel™ DM100™ (25-pin D-type
connector).

Also, it may be necessary to loopback control signals at the Nortel connector if it is not possible to disable
their function. The Nortel switch must be set to DCE mode.

A.1.2.3

Connecting an SPCI2S to an INET Tester

The following information has been used to connect an SPCI2S to an INET™ tester (Turbo7/Spectra) using a
25-pin D-type connector.

V.11 signal name

Port A pin on

SPCI2S

Port B pin on

SPCI2S

DKL26

Y-cable pin

M34 signal name

M34

pin

Received true data

26

9

4

RD-N

T

Received inv data

25

8

11

RD-P

R

Transmit true data

22

5

2

TD-N

S

Transmit inv data

21

4

9

TD-P

P

Receive true clock

24

7

6

XMITCLK(DCE)-N

AA

Receive inv clock

23

6

13

XMITCLK(DCE)-P

Y

Signal Ground

10

10

8

SIGNALGND

B

V.11 signal name

Port A pin on

SPCI2S

Port B pin on

SPCI2S

DKL26

Y-cable pin

Nortel signal name

Nortel

pin

Received true data

26

9

4

RxD-B

8

Received inv data

25

8

11

RxD-A

7

Transmit true data

22

5

2

TxD-B

2

Transmit inv data

21

4

9

TxD-A

1

Receive true clock

24

7

6

TSET-B

4

Receive inv clock

23

6

13

TSET-A

3

Signal Ground

10

10

8

ISOGND

21

V.11 signal name

Port A pin on

SPCI2S

Port B pin on

SPCI2S

DKL26

Y-cable pin

INET Signal name

INET

pin

Received true data

26

9

4

Receive Data – B

16

Received inv data

25

8

11

Receive Data - A

3

Transmit true data

22

5

2

Send Data – B

13

Transmit inv data

21

4

9

Send Data – A

2

Receive true clock

24

7

6

Send Timing - B

14

Receive inv clock

23

6

13

Send Timing – A

15

Signal Ground

10

10

8

Ground