ELECTRICAL REQUIREMENT CHART
To hook-up your spa, follow these instructions:

Model

Branch Cir .

Gauge

C h a i rman II 2 4 0 V, 38A 3 Wi re + gro u n d

5 0 A

#6 AW G

2 4 0 V, 32A 3 Wi re + gro u n d

4 0 A

#6 AW G

2 4 0 V, 24A 3 Wi re + gro u n d

3 0 A

#8 AW G

D i p l o m a t

2 4 0 V, 38A 3 Wi re + gro u n d

5 0 A

#6 AW G

2 4 0 V, 32A 3 Wi re + gro u n d

4 0 A

#6 AW G

2 4 0 V, 24A 3 Wi re + gro u n d

3 0 A

#8 AW G

C h a i rm a n

2 4 0 V, 38A 3 Wi re + gro u n d

5 0 A

#6 AW G

2 4 0 V, 32A 3 Wi re + gro u n d

4 0 A

#6 AW G

2 4 0 V, 24A 3 Wi re + gro u n d

3 0 A

#8 AW G

C a l i f o rn i a n

2 4 0 V, 38A 3 Wi re + gro u n d

5 0 A

#6 AW G

2 4 0 V, 32A 3 Wi re + gro u n d

4 0 A

#6 AW G

2 4 0 V, 24A 3 Wi re + gro u n d

3 0 A

#8 AW G

N a u t i l u s

2 4 0 V, 38A 3 Wi re + gro u n d

5 0 A

#6 AW G

2 4 0 V, 32A 3 Wi re + gro u n d

4 0 A

#6 AW G

2 4 0 V, 24A 3 Wi re + gro u n d

3 0 A

#8 AW G

A u rora II

2 4 0 V, 38A 3 Wi re + gro u n d

5 0 A

#6 AW G

2 4 0 V, 32A 3 Wi re + gro u n d

4 0 A

#6 AW G

2 4 0 V, 24A 3 Wi re + gro u n d

3 0 A

#8 AW G

Triad II

2 4 0 V, 30A 3 Wi re + gro u n d

4 0 A

#6 AW G

2 4 0 V, 24A 3 Wi re + gro u n d

3 0 A

#8 AW G

A u rora HP

2 4 0 V, 38A 3 Wi re + gro u n d

5 0 A

#6 AW G

2 4 0 V, 30A 3 Wi re + gro u n d

4 0 A

#6 AW G

2 4 0 V, 24A 3 Wi re + gro u n d

3 0 A

#8 AW G

I n t e r l u d e

2 4 0 V, 30A 3 Wi re + gro u n d

4 0 A

#6 AW G

2 4 0 V, 24A 3 Wi re + gro u n d

3 0 A

#8 AW G

A re n a

2 4 0 V, 30A 3 Wi re + gro u n d

4 0 A

#6 AW G

2 4 0 V, 24A 3 Wi re + gro u n d

3 0 A

#8 AW G

Tr i a d

2 4 0 V, 30A 3 Wi re + gro u n d

4 0 A

#6 AW G

2 4 0 V, 24A 3 Wi re + gro u n d

3 0 A

#8 AW G

Branch Cir .

Protection

Electrical

Rating