Alarm input alarm output, Alarm input, Alarm output – Digimerge DHU104 User Manual

Page 42

Advertising
background image

34

Event / Sensor

ALARM INPUT

Configurations for any external alarm
device (i.e. a Door or Window Sensor).
Refer to the appendices for hardware
configuration details.

Operation - Sets the Alarm Sensor

Connection Status (Enable / Disable)
for an external alarm (i.e. Door or
Window Sensors).

Type: Sets the Alarm Sensor type to

N/O (Normally Open) or N/C (Normally
Closed).

N/O (Normally Open) - Select for an Alarm

that has a Normally Open circuit (such as
a door that remains open). An Alarm will
occur when this is changed to a Closed
status.

N/C (Normally Closed) - Select for an

Alarm that has a Normally Closed circuit
(such as a Window Sensor). An Alarm will
occur when this is changed to a Opened
status.

ALARM OUTPUT

Sends an Alarm Out signal to a device
(such as a Manual Door or independent
Light/Buzzer Alarm) when an Alarm In
event is detected.

Note: You must have the option,
“Operation,” ENABLED in order to
configure the options in this menu.

Relay - By default, 1. Non-selectable.

Mode - Setup Reacted Relay as either

Latched or Transparent Mode:

• Latched – When sensor alarm activated,

relay reacted in setup duration.

• Transparent – Relay reacted temporary

during sensor alarm activate.

Type - Set the Relay Type to either N/

O (Normally Open) or N/C (Normally
Closed).

Operation - Setup Relay Connect with

Alarm Sensor to either Enable or
Disable.