Error messages, Ndesired sound does not come out, Nsound is interrupted or noise occurs – Marantz PM-10 Stereo 200W Power Amplifier (Black) User Manual

Page 27

Advertising
background image

n

Desired sound does not come out

Symptom

Cause / Solution

Page

No sound comes out of a specific

speaker.

0

Check that speaker cables are properly connected.

8

0

Adjust the left and right channel balance.

18

The left and right of stereo sound is

reversed.

0

Check whether the left and right speakers are connected to the correct speaker terminals.

8

n

Sound is interrupted or noise occurs

Symptom

Cause / Solution

Page

When playing a record, the sound is

distorted.

0

Adjust to a proper needle pressure.

0

Check the tip of the needle.

0

Replace the cartridge.

When playing a record, a humming

noise comes out of the speakers.

0

Check that the turntable is connected correctly.

10

0

If there is a TV or AV device near the turntable, such devices may affect the playback sound. Install the turntable in a location as far

away as possible from the TV or other AV devices.

When playing a record, a humming

noise comes out of the speakers when

the volume is high. (Howling

phenomenon)

0

Install the turntable and speakers as far from each other as possible.

10

0

The vibrations from the speakers are being transmitted to the player through the floor. Use cushions, etc., to absorb the speakers’

vibrations.

Error messages

When multiple amplifiers are connected by F.C.B.S., the error messages described in the table below may be displayed on the display. In such a case, ID number setting or remote cable

connection may be in failure. Check the ID number or remote cable connection, referring to the table below. For details on ID number setting, see “How to set ID number for F.C.B.S.” (

v

p. 12).

Indication

Meaning

Cause / Solution

ERROR 02

Multiple amplifiers take ID No.2.

0

Assign different ID numbers to the amplifiers.

ERROR 03

Multiple amplifiers take ID No.3.

ERROR 04

Multiple amplifiers take ID No.4.

ERROR 11

The amplifiers with ID No.2-4 cannot communicate with the amplifier with ID No.1.

0

If the amplifier with ID No.1 is not on, turn it ON.

0

Check that the remote cable is properly connected.

ERROR 12

The amplifier with ID No.1 cannot communicate with the amplifiers with ID No.2-4.

0

If multiple amplifiers take ID No.1, set ID numbers properly.

0

If the amplifier with ID No.1 is connected to the amplifier with ID No.0, set ID

numbers properly.

0

Check that the remote cable is properly connected.