10/U
10/U;20/T;30/T
10/T;20/T

Note

If a hyphen ("-") is entered, VLAN settings will not be performed.
This section will be ignored for PRIMERGY BX900/BX400 LAN switch blades operating in IBP mode.
The settings in this section will be ignored for a LAN switch blade PY CB DCB SW 10Gb 18/6/6.

Server Management Information

-

Section Name

Enter [Server] as the section name.

-

Section Header

operation

Enter the desired operation for the current line. Enter a hyphen ("-") to skip this line.

chassis_name

Enter the chassis name (the value of "chassis_name" in the [Chassis] section).

Note

This field is only required for PRIMERGY BX servers.

slot_no

Enter the slot number where the server blade is installed. Enter a number between 1 and 18.

Note

-

This field is only required for PRIMERGY BX servers.

-

When a server blade is registered, Resource Orchestrator does not check the actual slot position, or whether it has been installed
properly.

-

When registering multi-slot servers, enter only the master slot number.

server_name

Enter the resource name that will be used to identify the server. Enter a character string beginning with an alphabetical character
and containing up to 15 alphanumeric characters and hyphens ("-"). If enclosed by parentheses "( )", this server will be seen as
being in a switched over state, and this line will be ignored when importing the system definition file.

Note

Server names should be unique between all servers. Names are not case-sensitive.