Parameters – MITSUBISHI ELECTRIC MR-J2S- A User Manual
Page 140
5 - 17
5. PARAMETERS
Class No. Symbol
Name and function
Initial
value
Unit
Setting
range
Control
mode
39
VDC
Speed differential compensation
Used to set the differential compensation.
Made valid when the proportion control (PC) is switched on.
980
0
to
1000
P S
40
For manufacturer setting
Do not change this value by any means.
0
P S T
41
*DIA Input signal automatic ON selection
Used to set automatic Servo-on (SON) forward rotation stroke end
(LSP) reveres rotation stroke end (LSN).
Servo-on (SON) input selection
0: Switched on/off by external input.
1: Switched on automatically in servo amplifier.
(No need of external wiring)
Forward rotation stroke end
(LSP) input selection
0: Switched on/off by external input.
1: Switched on automatically in servo amplifier.
(No need of external wiring)
Reverse rotation stroke end (LSN)
input selection
0: Switched on/off by external input.
1: Switched on automatically in servo amplifier.
(No need of external wiring)
0
0000
Refer to
Name
and
function
column.
P S
P/S
S/T
T/P
E
xpa
n
si
on
pa
ra
m
et
ers
1
42
*DI1
Input signal selection 1
Used to assign the control mode changing signal input pins and to set
the clear (CR).
Control change (LOP) input pin assignment
Used to set the control mode change signal input
connector pins. Note that this parameter is made valid
when parameter No.
0 is set to select the position/speed, speed/torque or
torque/position change mode.
Set
value
0
Connector pin No.
CN1B-5
1
CN1B-14
2
CN1A-8
3
CN1A-7
4
CN1B-8
5
CN1B-9
Clear (CR) selection
0: Droop pulses are cleared on the leading edge.
1: While on, droop pulses are always cleared.
0 0
0003
Refer to
Name
and
function
column.
P