Parameters – MITSUBISHI ELECTRIC MR-J2S- A User Manual

Page 140

Advertising
background image

5 - 17

5. PARAMETERS

Class No. Symbol

Name and function

Initial
value

Unit

Setting

range

Control

mode

39

VDC

Speed differential compensation

Used to set the differential compensation.
Made valid when the proportion control (PC) is switched on.

980

0

to

1000

P S

40

For manufacturer setting

Do not change this value by any means.

0

P S T

41

*DIA Input signal automatic ON selection

Used to set automatic Servo-on (SON) forward rotation stroke end
(LSP) reveres rotation stroke end (LSN).

Servo-on (SON) input selection
0: Switched on/off by external input.
1: Switched on automatically in servo amplifier.
(No need of external wiring)

Forward rotation stroke end
(LSP) input selection
0: Switched on/off by external input.
1: Switched on automatically in servo amplifier.
(No need of external wiring)

Reverse rotation stroke end (LSN)
input selection
0: Switched on/off by external input.
1: Switched on automatically in servo amplifier.
(No need of external wiring)

0

0000

Refer to
Name
and
function
column.

P S

P/S
S/T
T/P

E

xpa

n

si

on

pa

ra

m

et

ers

1

42

*DI1

Input signal selection 1

Used to assign the control mode changing signal input pins and to set
the clear (CR).

Control change (LOP) input pin assignment
Used to set the control mode change signal input
connector pins. Note that this parameter is made valid
when parameter No.
0 is set to select the position/speed, speed/torque or
torque/position change mode.

Set

value

0

Connector pin No.

CN1B-5

1

CN1B-14

2

CN1A-8

3

CN1A-7

4

CN1B-8

5

CN1B-9

Clear (CR) selection
0: Droop pulses are cleared on the leading edge.
1: While on, droop pulses are always cleared.

0 0

0003

Refer to
Name
and
function
column.

P