3 changing the status display screen, Display and operation – MITSUBISHI ELECTRIC MR-J2S- A User Manual
Page 161
6 - 4
6. DISPLAY AND OPERATION
Name
Symbol
Unit
Description
Display
range
Within one-revolution
position high
Cy2
100
pulse
The within one-revolution position is displayed in 100 pulse
increments of the encoder.
The value returns to 0 when it exceeds the maximum number of
pulses.
The value is incremented in the CCW direction of rotation.
0
to
1310
ABS counter
LS
rev
Travel value from the home position in the absolute position
detection systems is displayed in terms of the absolute position
detectors counter value.
32768
to
32767
Load inertia moment
ratio
dC
Times
The estimated ratio of the load inertia moment to the servo motor
shaft inertia moment is displayed.
0.0
to
300.0
Bus voltage
Pn
V
The voltage (across P-N) of the main circuit converter is displayed.
0
to
450
6.2.3 Changing the status display screen
The status display item of the servo amplifier display shown at power-on can be changed by changing the
parameter No. 18 settings.
The item displayed in the initial status changes with the control mode as follows.
Control mode
Status display at power-on
Position
Cumulative feedback pulses
Position/speed
Cumulative feedback pulses/servo motor speed
Speed
Servo motor speed
Speed/torque
Servo motor speed/analog torque command voltage
Torque
Analog torque command voltage
Torque/position Analog torque command voltage/cumulative feedback pulses