Page 269
13 - 40
13. OPTIONS AND AUXILIARY EQUIPMENT
(5) Specifications
Power regeneration common converter
FR-CV-
Item
7.5K
11K
15K
22K
30K
37K
55K
Total of connectable servo amplifier capacities [kW]
3.75
5.5
7.5
11
15
18.5
27.5
Maximum servo amplifier capacity
[kW]
3.5
5
7
11
15
15
22
Total of connectable servo motor rated
currents
[A]
33
46
61
90
115
145
215
Short-time
rating
Total capacity of applicable servo motors, 300% torque, 60s (Note1)
Output
Regenerative
braking torque
Continuous
rating
100% torque
Rated input AC voltage/frequency
Three-phase 200 to 220V 50Hz, 200 to 230V 60Hz
Permissible AC voltage fluctuation
Three-phase 170 to 242V 50Hz, 170 to 253V 60Hz
Permissible frequency fluctuation
5%
Power supply
Power supply capacity(Note2) [kVA]
17
20
28
41
52
66
100
Protective structure (JEM 1030), cooling system
Open type (IP00), forced cooling
Ambient temperature
-10 (14 ) to +50 (122 ) (non-freezing)
Ambient humidity
90%RH or less (non-condensing)
Environment
Ambience
Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt)
Altitude, vibration
1000m or less above sea level, 5.9m/s
2
or less
No-fuse breaker or leakage current breaker
30AF
30A
50AF
50A
100AF
75A
100AF
100A
225AF
125A
225AF
125A
225AF
175A
Magnetic contactor
S-N20
S-N35
S-N50
S-N65
S-N95
S-N95
S-N125
Note 1. This is the time when the protective function of the FR-CV is activated. The protective function of the servo amplifier is activated
in the time indicated in section 12.1.
2. When connecting the capacity of connectable servo amplifier, specify the value of servo amplifier.