Diagnostics menu – Integra CROMA24 User Manual
Page 68
68
Maintenance
Croma24 Service Manual
Figure 3-24. Deadband Slow/Fast Display.
Figure 3-24 shows what the display will look like when printing
either the fast or slow test if it is out of alignment. A correctly
aligned printer will appear as if there is only a series of vertical lines
printed. No differences will be apparent between the segments in
each set of lines .
The SLOW DEADBAND calibration is a precision test that checks
the firing time of the jets as related to the forward and reverse
direction.
Allowable values for the Slow Deadband is -1, 0 and 1, and from 0 to
164 in increments of one for the Fast Deadband.
The Single Line Test and All Line Test are variations of the Slow and
Fast Tests except they print longer lines so that long time integra-
tion of the deadband calibration can be observed. The Single Line
Test prints only one line at a time while the All Line Test prints all
lines at the same time.
Diagnostics Menu
Figure 3-25. Diagnostics Menu.