Networking

5-23

Automation System S7-400 Hardware and Installation

A5E00850741-01

Optical PROFIBUS-DP Network in Partyline Topology

The optical PROFIBUS-DP network with nodes that have an integrated fiber-optic

cable interface has a partyline topology. The PROFIBUS nodes are

interconnected in pairs by means of Duplex fiber-optic cables.
Up to 32 PROFIBUS nodes with a fiber-optic cable interface can be

series-connected in an optical PROFIBUS-DP network. If a PROFIBUS node fails,

as a result of the partyline topology none of the downstream DP slaves can be

accessed by the DP master.

Programming

device/PC/OP

PROFIBUS

cable

Optical PROFIBUS-DP

Distances between 2

nodes:

Plastic fiber-optic cable up

to 50 m

PCF fiber-optic cable up to

300 m

OBT

OBT

S7-400 with IM 467 FO

ET 200M with

IM 153-2 FO

Other field devices without

fiber-optic cable interface

Other

nodes

Figure 5-13 Optical PROFIBUS-DP Network with Nodes that have an Integrated Fiber-Optic Cable

Interface

Transmission Rate

The following transmission rates are possible when the optical PROFIBUS-DP

network is operated with a partyline topology:

• 9.6 kbps

• 19.2 kbps

• 45.45 kbps

• 93.75 kbps

• 187.5 kbps

• 500 kbps

• 1.5 Mbps

• 12 Mbps