Chapter 4 analog input, Figure 4-1. ni 6232/6233 analog input circuitry, Analog input circuitry – National Instruments NI 6232 User Manual
Page 28: Analog input circuitry -1, Of chapter 4, Analog input
© National Instruments Corporation
4-1
4
Analog Input
Figure 4-1 shows the analog input circuitry of NI 6232/6233 devices.
Figure 4-1. NI 6232/6233 Analog Input Circuitry
Analog Input Circuitry
I/O Connector
You can connect analog input signals to the M Series device through the I/O
connector. The proper way to connect analog input signals depends on the
analog input ground-reference settings, described in the
section. Also refer to Appendix A,
, for device I/O connector pinouts.
MUX
Each M Series device has one analog-to-digital converter (ADC). The
multiplexers (MUX) route one AI channel at a time to the ADC through the
NI-PGIA.
DIFF,
RSE,
or NRSE
I/O Connector
AI <0..
n>
Mux
AI GND
NI-PGIA
AI Terminal
Configuration
Selection
Input Range
Selection
ADC
AI Data
Isolation
Barrier
Digital
Isolators
AI FIFO