Chapter 7

Counters

NI 6232/6233 User Manual

7-26

ni.com

Nyquist frequency of the system. Figure 7-28 shows an example of pulse
generation for ETS; the delay from the trigger to the pulse increases after
each subsequent Gate active edge.

Figure 7-28. Pulse Generation for ETS

For information on connecting counter signals, refer to the

Default Counter

Terminals

section.

Counter Timing Signals

M Series devices feature the following counter timing signals.

Counter n Source

Counter n Gate

Counter n Aux

Counter n A

Counter n B

Counter n Z

Counter n Up_Down

Counter n HW Arm

Counter n Internal Output

Counter n TC

Frequency Output

In this section, n refers to either Counter 0 or 1. For example, Counter n
Source refers to two signals—Counter 0 Source (the source input to
Counter 0) and Counter 1 Source (the source input to Counter 1).

OUT

D1

D2 = D1 +

ΔD

D3 = D1 + 2

ΔD

GATE