µ

PD17062

Fig. 12-6 Timing Chart

As shown in Fig. 12-6, the positive-going edge of the internal 10 Hz pulse starts the program at 000H at

a power-on reset.

When the BTM0CY flag is checked at point A, it appears to be reset to 0, thus indicating a power-on reset,

because it is just after the power is turned on.

When a power-on reset occurs, process C is performed to specify the timer carry FF set pulse as 100 ms.

Because the timer carry FF was read-accessed once at point A, the BTM0CY flag is set to 1 at intervals of

100 ms.

Even when the CE pin goes low at point B and high at point C, the program continues updating the clock

while performing process B unless a clock stop instruction has been executed.

Because the CE pin goes from a low to a high at point C, a CE reset occurs at point D, where the timer carry

FF set pulse rises for the second time, thus starting the program at 0000H.

When the BTM0CY flag is checked at point E, a backup (CE reset) is detected because the BTM0CY flag is

already set to 1.

As seen from the timing chart, if the clock is not updated by 100 ms at point E, the clock loses 100 ms each

time a CE reset occurs.

If process A (power failure check) takes longer than 100 ms at point E, the program loses twice a chance

of detecting when the BTM0CY flag is set; therefore, process A must be completed within 100 ms.

To put in another way, checking the BTM0CY flag for power failure must be performed before the timer

carry FF is set after the program starts at 0000H.

A

C

B

B

B

B

B

B

B

B

B

B

A

B

B

B

%

%

%

% %

% %

% %

#

% %

5 V

0 V

V

DD

CE

Internal pulse

10 Hz

Timer carry FF

set pulse

BTM0CY flag

Program

processing

Program

instruction

Supply voltage

applied

Start at address 0
on a power-on reset

Timer
incre-
mented

Timer
incre-
mented

Timer
incremented

Timer
incremented

Timer
incremented

BTM0CY flag detected

Start at

address 0

on a CE

reset

Timer updated because
the BTM0CY flag has
been detected to be
set to 1

Point A

Point B

Point C

Point D

Point E

#

%

Advertising