Figure 4-22. scanclk signal timing, Extstrobe* signal, Figure 4-23. extstrobe* signal timing – National Instruments NI 6014 User Manual

Page 56: Extstrobe* signal -30

Advertising
background image

Chapter 4

Connecting Signals

NI 6013/6014 User Manual

4-30

ni.com

Figure 4-22 shows the timing for SCANCLK.

Figure 4-22. SCANCLK Signal Timing

Note

When using NI-DAQ, SCANCLK polarity is low-to-high and cannot be changed

programmatically.

EXTSTROBE* Signal

EXTSTROBE* is an output-only signal that generates either a single pulse
or a sequence of eight pulses in the hardware-strobe mode. An external
device can use this signal to latch signals or to trigger events. In the
single-pulse mode, software controls the level of EXTSTROBE*. A 10

µs

and a 1.2

µs clock are available for generating a sequence of eight pulses in

the hardware-strobe mode.

Figure 4-23 shows the timing for the hardware-strobe mode
EXTSTROBE* signal.

Figure 4-23. EXTSTROBE* Signal Timing

Note

EXTSTROBE* cannot be enabled through NI-DAQ.

t

w

= 400 to 500 ns

t

d

= 50 to 100 ns

CONVERT*

SCANCLK

t

d

t

w

V

OH

V

OL

t

w

t

w

t

w

= 600 ns or 500

s