Timing i/o – National Instruments NI 6014 User Manual

Page 76

Advertising
background image

Appendix A

Specifications

© National Instruments Corporation

A-7

NI 6013/6014 User Manual

Power-on state ........................................ Input (high-impedance),

1.5 k

Ω pull down to DGND

Data transfers ......................................... Programmed I/O

Max transfer rate .................................... 50 kwords/s, system dependent

Timing I/O

Number of channels ............................... 2 up/down counter/timers,

1 frequency scaler

Resolution

Counter/timers ................................ 24 bits

Frequency scalers............................ 4 bits

Compatibility ......................................... TTL/CMOS

Base clocks available

Counter/timers ................................ 20 MHz, 100 kHz

Frequency scalers............................ 10 MHz, 100 kHz

Base clock accuracy ............................... ±0.01%

Max source frequency ............................ 20 MHz

Min source pulse duration...................... 10 ns in edge-detect mode

Min gate pulse duration.......................... 10 ns in edge-detect mode

Data transfers ......................................... DMA, interrupts,

programmed I/O

DMA modes ........................................... Scatter-gather

(Single transfer, demand transfer)

Number of DMA channels ..................... 1

1

1

The NI 6013/6014 has one DMA channel to be shared by all resources on the device.

Advertising