How can I use the STARTSCAN and CONVERT* signals on the
NI 6013/6014 to sample the AI channel(s)?

The NI 6013/6014 uses the STARTSCAN and CONVERT* signals to
perform interval sampling. As Figure C-2 shows, STARTSCAN controls
the scan interval, which is determined by the following equality:

Figure C-2. Scan Interval

CONVERT* controls the interchannel delay, which is determined by the
following equality:

This method allows multiple channels to be sampled relatively quickly in
relationship to the overall scan rate, providing a nearly simultaneous effect
with a fixed delay between channels.

1

scan interval

-------------------------------

scan rate

=

Channel 0

Channel 1

Interchannel Delay

Scan Interval

1

interchannel delay

--------------------------------------------

sampling rate

=