Before using this product, 1 receiving instructions, 2 appearance – GE Industrial Solutions AF-300 G11 User Manual
Page 14
1-1
Data subject to change without notice 7/07. © 2007 GE Drives
1. Before Using This Product
1.1 Receiving Instructions
40 HP or more
Mounting screws of
surface cover
(Total of 6 screws)
Lifting
Holes
(4 holes
total)
Ratings
Nameplate
Surface Cover
Keypad Panel
Mounting screws of surface cover
Keypad Panel
Surface
cover
Intermediate cover
Ratings nameplate
30 HP or less
Ratings Nameplate
Unpack and check the product as explained below.
If you have any questions about the product, contact GE
Drives or your local GE Drives distributor.
1.
Check the ratings nameplate to confirm that the
delivered product is the one that was ordered.
2.
Check for damaged and/or missing parts upon delivery.
3.
In addition to the drive unit and this manual, the package contains rubber bushings (for products with 30 Hp or less)
and a terminating resistor (1/2 W, 120 ohm). The terminating resistors for products with 30 Hp or less is packaged
separately. The terminating resistors for products with 40HP or more are installed internal to the drive unit. To
connect the internal terminating resistor, place hardware jumper J2 to the “ON” position. This terminating resistor is
required for RS485 RTU communication.
4.
On drives rated 100 Hp and larger a separately mounted DC Link Reactor is provided. The reactor should be checked
for proper rating before installation.
1.2 Appearance
SER. No. : 9 9 1 0 - 0 0 0 1 2 M 0 0 01
Production lot serial number
Production week: Fiscal week (01 to 53)
Production year: Last two digits of year (99 = 1999)