Section 4 Maintenance

Installation and Operation Manual

X-TMF-5850i-MFC-eng

Part Number: 541B108AAG

December, 2008

4-5 Use of the Conversion Tables

If a mass flow controller is operated on a gas other than the gas it was
calibrated with, a scale shift will occur in the relation between the output
signal and the mass flow rate. This is due to the difference in heat
capacities between the two gases. This scale shift can be approximated by
using the ratio of the molar specific heat of the two gases or by sensor
conversion factor. A list of sensor conversion factors is given in Table 4-3.
To change eo a new gas, multiply the output reading by the ratio of the gas
factor for the desired gas to the gas factor for the calibration gas.

Actual gas

=

Output

x

factor of the new gas

flow rate

reading

factor of the calibrated gas

Example:
The controller is calibrated for Nitrogen.
The desired gas is Carbon Dioxide.
The output reading is 75 sccm when Carbon Dioxide is flowing.
Then 75 x 0.78 = 58.50 sccm

In order to calculate the conversion factor for a gas mixture, the following
formula should be used:

Where,
P1 = percentage (%) of gas 1 (by volume)
P2 = percentage (%) of gas 2 (by volume)
Pn = percentage (%) of gas n (by volume)
Example: The desired gas is 20% Helium (He) and 80% Chlorine
(Cl) by volume. The desired full scale flow rate of the mixture is 20
slpm. Sensor conversion factor for the mixture is:

Air equivalent flow = 20/.903 = 22.15 slpm air

It is generally accepted that the mass flow rate derived from this equation
is only accurate to ±5%. The sensor conversion factors given in Table 4-3
are calculated based on a gas temperature of 21°C and a pressure of one
atmosphere. The specific heat of most gases is not strongly pressure- and/
or temperature-dependent. However, gas conditions that vary widely, from
these reference conditions, may cause an additional error due to the
change in specific heat caused by temperature and/or pressure.