Expanded sio specification (optional) – IAI America XSEL-KE User Manual

Page 327

Advertising
background image

312

Appendix

 Expanded SIO Specification (Optional)

Type

IA-105X-MW-A

(for RS232 connection)

IA-105X-MW-B

(for RS422 connection)

IA-105X-MW-C

(for RS485 connection)

(1) Specification

An SIO expansion board is a D-sub, 15-pin interface used for both RS232 and RS422 connection.

The terminal assignments allow selection of RS232, RS422 or RS485 in accordance with the
wiring. (The controller is shipped with a joint cable appropriate for the selected communication
method.)

Specifications

Item

Description

Connector

D-sub, 15-pin (male D-sub connector)

Connector name

CN3 connector

Maximum baud rate

115.2K

Maximum connection

distance

10M (RS232) / 600M (RS422)

38.4K (RS232C), 115.2K (RS422)

Interface standards

RS232 / RS422 / RS485

Communication method

Start-stop synchronous full/half-duplex communication

Character length

7/8 bits

Start bit

1 bit

Stop bit

1/2 bits

Parity

None, even, odd

Connection cable

Special 15-pin cable

1

Out

SD (TXD)

Transmitted data

2

In

RD (RXD)

Received data

3

Out

RS (RTS)

Request to send

4

In

CS (CTS)

Clear to send

5

Out

DR (DTR)

Equipment ready

6

In

ER (DSR)

Data set ready

7

SG

Signal

ground

8

N.C.

Not

used

9

N.C.

Not

used

10

N.C.

Not

used

11

In

RDA (RXD +)

Received data



,Q

5'% 5;'± 

Received data

13 In

TRM

Termination

connection



2XW

6'% 7;'± 

Transmitted data

Terminal assignments

15

Out

SDA (TXD +)

Transmitted data