Setup page parameter table, Retransmit output x (1 and 2), Alarm output x (1 and 2) – Watlow Series F4S/D User Manual
Page 60
5 . 1 2
■
S e t u p
Wa t l o w S e r i e s F 4 S / D
Setup Page Parameter Table
Modbus
Register
Range
read/write
Conditions for
Parameter
Description
(Modbus Value)
Default
(I/O, Set, Ch)
Parameters to Appear
✔ NOTE:
Press the Information Key
ˆ for more task-related tips.
Setup Page Parameter Table
Modbus
Register
Range
read/write
Conditions for
Parameter
Description
(Modbus Value)
Default
[I/O, Set, Ch]
Parameters to Appear
Active: Always.
Output
710
[1]
727
[2]
r/w
Low end of
sensor
range
-19999 to high scale -1
(minimum sensor
range) (-19999 to
High Scale -1)
Low Scale
Set low end of cur-
rent or voltage
range to retransmit.
Active: Always.
Output
836
[1]
837
[2]
r/w
4 to 20mA (0)
4 to 20mA (0)
0 to 20mA (1)
0 to 5V (2)
1 to 5V (3)
0 to 10V (4)
Analog Range
Select voltage or
current range to
retransmit.
Active: Always. (Values appear
only if the source is enabled.)
Output
709
[1]
726
[2]
r/w
Input 1 (0)
Input 1 (0)
Input 2 (1)
Input 3 (2)
Set Point 1 (3)
Set Point 2 (4)
Channel 1 Power (5)
Channel 2 Power (6)
Retransmit Source
Choose a source for
retransmit signal.
Main > Setup > Retransmit Output x (1 and 2)
Retransmit Output x (1 and 2)
Active if Alarm Output is en-
abled.
Output
708
[1]
725
[2]
r/w
Yes on Main
Page (0)
Yes on Main Page (0)
No (1)
Alarm Messages
Select the alarm
message option.
Active if Alarm Output is
enabled.
Output
707
[1]
724
[2]
Open on
Alarm (0)
Open on Alarm (0)
Close on Alarm (1)
Alarm Logic
Select the alarm
logic option.
Active if Alarm Output is
enabled.
Output
706
[1]
723
[2]
r/w
Both (0)
Both (0)
Low (1)
High (2)
Alarm Sides
Choose to enable
Low, High or both
alarm set points.
Active if Alarm Output is
enabled.
Output
703
[1]
720
[2]
r/w
3 (3)
1 to 30000
(1 to 30000)
Alarm Hysteresis
Set the alarm
hysteresis.
Active if Alarm Output is
enabled.
Output
705
[1]
722
[2]
r/w
No (0)
No (0)
Yes (1)
Silencing
Choose whether to
mask alarms on
power-up.
Active if Alarm Output is
enabled.
Output
704
[1]
721
[2]
r/w
Alarm Self-
Clears (0)
Alarm Self-Clears (0)
Alarm Latches (1)
Latching
Choose automatic or
manual clearing of
alarms.
Active if the source is
enabled.
Output
716
[1]
733
[2]
r/w
Off (0)
Input 1 (0)
Input 2 (1)
Input 3 (2)
Alarm Source
Select the alarm
source.
Active always.
Output
702
[1]
719
[2]
r/w
Off (0)
Off (0)
Process (1)
Deviation (2)
Alarm Type
Select the alarm
type.
Active always.
3200-3209
3210-3219
r/w
ALARMX
<selected by user>
(ASCII Values)
Name
Name the alarm for
easy reference.
Main > Setup > Alarm Output x (1 and 2)
Alarm Output x (1 and 2)