Correcting device login issues

To try to pinpoint problems with device logins, use this procedure:

1.

Log in to the switch as root.

2.

Issue the

switchshow

command; then check for correct logins. For example:

switch:admin> switchshow
switchName: sw094135
switchType: 26.1
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 126
switchId: fffc7e
switchWwn: 10:00:00:05:1e:34:00:69
zoning: ON (cfg_em)
switchBeacon: OFF
Port Media Speed State
=========================
0 id N1 Online E-Port 10:00:00:60:69:11:f9:fc
“2800_116”
1 id 1G Online E-Port 10:00:00:60:69:11:f9:fc
“2800_116”
2 id N2 No_Light
3 id 2G No_Light
4 id N2 Online E-Port (Trunk port, master is Port 5)
5 id N2 Online E-Port 10:00:00:05:1e:34:00:8b
“Dazz125” (downstream)(Trunk master)
6 id N2 No_Light
7 id N2 No_Light
8 id N1 Online L-Port 4 public, 1 private, 1 phantom
9 id N2 No_Light
10 id N2 Online G-Port
11 id N2 Online F-Port 10:00:00:01:c9:28:c7:01
12 id N1 Online L-Port 4 public, 1 private, 1 phantom
13 -- N2 No_Module
14 id N2 Online E-Port (Trunk port, master is Port 15)
15 id N2 Online E-Port 10:00:00:60:69:90:03:17
“TERM_113” (downstream)(Trunk master)