Using legacy commands for snmpv1 – HP Brocade 4Gb SAN Switch for HP BladeSystem p-Class User Manual

Page 64

Advertising
background image

64

Configuring standard security features

To display the mibCapability configuration, use the following as an example:

To change the systemGroup configuration to default, use the following as an example:

Using legacy commands for SNMPv1

Use the

snmpconfig

command to configure the SNMPv1 agent and traps (see ”

Using the snmpconfig

command

” on page 61). However, if necessary for backward compatibility, you can choose to use

legacy commands.

switch:admin> snmpconfig --show mibCapability

FA-MIB: YES

FICON-MIB: YES

HA-MIB: YES

SW-TRAP: YES

swFCPortScn: YES

swEventTrap: YES

swFabricWatchTrap: YES

swTrackChangesTrap: NO

FA-TRAP: YES

connUnitStatusChange: YES

connUnitEventTrap: NO

connUnitSensorStatusChange: YES

connUnitPortStatusChange: YES

SW-EXTTRAP: NO

FICON-TRAP: NO

HA-TRAP: YES

fruStatusChanged: YES

cpStatusChanged: YES

fruHistoryTrap: NO

switch:admin> snmpconfig --default systemGroup

*****

This command will reset the agent's system group configuration back
to factory default

*****

sysDescr = Fibre Channel Switch

sysLocation = End User Premise

sysContact = Field Support

authTraps = 0 (OFF)

*****

Are you sure? (yes, y, no, n): [no] y