Testing your calibration – AMX Modero NXD/NXT-1200VG User Manual

Page 98

Advertising
background image

Panel Calibration

84

VG-Series Modero Touch Panels

3.

After the "Calibration Successful." message appears, press anywhere on the screen to continue and
return to the Setup page.

Testing your Calibration

1.

Press and hold down the on-screen Calibration button for 6 seconds to enter the Calibrate page.

2.

Press anywhere on this page to confirm the on-screen crosshairs match your touch points.

3.

If the crosshairs do not appear directly below your LCD touch points, press the Back button and
recalibrate the panel using the above steps.

4.

Exit the Calibrate page by pressing the Back button to return to the Protected Setup page.

FIG. 69

Touch Panel Calibration Screens

The request to touch the crosshairs
is the first on-screen message

Calibration successful is the second
on-screen message that appears

On-screen crosshairs used for
calibration of the touch device

after the calibration process is
completed

If the calibration was improperly set and you cannot return to the Calibrate
page (through the panel’s firmware);
you can access this firmware page via
G4 WebControl where you can navigate to the Protected Setup page and press the
Calibrate button through your VNC window.
This action causes the panel to go to the Calibrate page seen above, where you can
physically recalibrate the actual touch panel again using the above procedures.