Inverter, Ay-xpc9/12jr, Single / multi type – Sharp AY-XP9RMR-AE-X9RMR User Manual

Page 10: R410a, Deluxe, Specifi cation

Advertising
background image

9

Deluxe

AY-XPC9/12JR

Features

Cool/Dry/Heat

Outdoor unit

AE-X9JR AE-X12JR

R410A

• Can be used singly

or in a multi split system

• Coanda Airfl ow System

Model

AY-XPC9JR

2.50 (0.90 – 3.00)

3.20 (0.90 – 5.00)

5.1

3.9

Cooling operation

Heating operation

Capacity (kW)

(Min. – Max.)

Capacity (kW)

(Min. – Max.)

SEER

SCOP

AY-XPC12JR

3.50 (0.90 – 3.80)

4.00 (0.90 – 5.70)

5.1

4.0

A

+A

A

A

Specifi cation

Model

Indoor

AY-XPC9JR

AY-XPC12JR

Outdoor

AE-X9JR

AE-X12JR

Preformance*1

Cooling

Energy Effi ciency Class

A

A

SEER

5.1

5.1

Pdesign

kW

2.5

3.5

Capacity (Min. – Max.)

kW

2.50 (0.90 – 3.00)

3.50 (0.90 – 3.80)

Input (Min. – Max.)

W

625 (200 – 900)

1,090 (200 – 1,300)

Annual electricity consumption*2

kWh/a

171

239

Heating
(Average
Climate)

Energy Effi ciency Class

A

A+

SCOP

3.9

4.0

Pdesign

kW

3.2

3.5

Capacity (Min. – Max.)

kW

3.20 (0.90 – 5.00)

4.00 (0.90 – 5.70)

Input (Min. – Max.)

W

760 (180 – 1,450)

1,020 (180 – 1,650)

Annual electricity consumption*2

kWh/a

1,126

1,221

Nominal Effi ciency*3

EER

4.00

3.21

COP

4.21

3.92

Nominal Current*3

Cooling

A

3.1

4.9

Heating

A

3.7

4.6

Sound Pressure Level*4 (Cool)

Indoor (Hi/Lo)

dB(A)

37/26

40/27

Outdoor

db(A)

45

48

Sound Power Level (Cool)

Indoor (Hi)

52

56

Outdoor

58

61

Airfl ow Volume (Hi, Cool)

m3/min

9.1

10.5

Operation Range (Outdooor)

Coolong

°C

-10 – 46

-10 – 46

Heating

°C

-15 – 24

-15 – 24

Model

Indoor

AY-XPC9JR

AY-XPC12JR

Outdoor

AE-X9JR

AE-X12JR

Power Supply

Outdoor

V/Phase/Hz 220 – 240/single/50 220 – 240/single/50

Dimensions

Indoor (WxHxD)

mm

790x278x198

790x278x198

Outdoor (WxHxD)

mm

730x540x250

730x540x250

Weight

Indoor

kg

10

10

Outdoor

kg

33

33

Min. – Max. Pipe Lenght

m

1 – 15

1 – 15

Max. Height Difference

m

7

7

Max. Chargless Lenght

m

10

10

Pipe Diameter

Liquid Side

inch

1/4

1/4

Gas Side

inch

3/8

3/8

Refrigerant (GWP*5)

kgCO

2

eq.

R410A (1975)

R410A (1975)

*1 According to EN14825
*2 Energy consumption “XYZ” kWh per year, based on standard test results. Actual energy

consumption will depend on how the appliance is used and where it is located.

*3 According to EN14511
*4 Sound pressure level is measured according to JIS C 9612.
*5 Refrigerant leakage contributes to climate change. Refrigerant with lower global
warming potential (GWP) would contribute less to global warming than a refrigerant

with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fl uid

with a GWP equal to 1975. This means that if 1 kg of this refrigerant fl uid would be leaked

to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg

of CO

2

, over a period of 100 years. Never try to interfere with the refrigerant circuit

yourself or disassemble the product yourself and always ask a professional.

INVERTER

SINGLE / MULTI TYPE

Advertising