Inverter, Multi type, Indoor units – Sharp AY-XP9RMR-AE-X9RMR User Manual

Page 18: 17 specification

Advertising
background image

17

Specification

Capacity Table

2-indoor units with AE-X2M14LR

2-indoor units with AE-X2M18KR

2-indoor units with AE-X2M18KR

Outdoor Units

System

2-indoor operation

2-indoor oparation

3-indoor operation

4-indoor operation

4-indoor operation

Model

Outdoor

AE-X2M14LR

AE-X2M18KR

AE-X3M18JR

AE-XM24HR

AE-XM30GR

Indoor Unit Combination*4

7+7

9+9

7+7+7

7+7+7+7

9+7+7+7

Capacity*1

Cool (Min. – Max.)

kW

3.80 (1.80 – 4.30)

5.20 (1.80 – 6.00)

5.20 (2.20– 7.00)

7.00 (3.00 – 8.20)

8.40 (4.30 – 9.00)

Heat (Min. – Max.)

kW

4.40 (1.90 – 5.40)

5.80 (1.90 – 7.30)

6.8 (2.20 – 8.40)

8.00 (3.00 – 9.20)

9.00 (4.40 – 10.60)

Power Supply

V/Phase/Hz

230/1ш/50

230/1ш/50

230/1ш/50

230/1ш/50

230/1ш/50

Running Current*1

Cool

A

4.1

7.0 (1.6 – 9.4)

6.5 (2.2 –11.3)

10.0 (2.7 – 13.6)

13.7 (4.9 – 16.0)

Heat

A

4.4

6.7 (1.7 – 9.6)

7.6 (1.9 – 11.4)

9.2 (2.6 – 11.7)

11.0 (4.3 – 14.0)

Power Input*1

Cool (Min. – Max.)

W

900 (350 – 1,160)

1,530 (350 – 2,050)

1,410 (430 – 2,460)

2,180 (600 – 2,980)

2,990 (1,070 – 3,490)

Heat (Min. – Max.)

W

950 (370 – 1,300)

1,450 (370 – 2,100)

1,660 (420 – 2,480)

2,000 (560 – 2,560)

2,400 (940 – 3,060)

Cooling Mde*2 (Average)

SEER

6.4

6.2

6.0

6.2

5.2

Energy Efficiency Class

A++

A++

A+

A++

A

Annual Electricity Consumption*5

kWh/a

207

292

301

393

564

P Design

kW

3.8

5.2

5.2

7.0

8.4

Heating Mode*2 (Average)

SCOP

4.4

4.2

4.1

4.3

3.9

Energy Efficiency Class

A+

A+

A+

A+

A

Annual Electricity Consumption*5

kWh/a

1109

1469

1851

2062

2636

P Design

kW

3.5

4.4

5.4

6.3

7.3

Declared Capacity

dB(A)

2.8

3.5

4.8

5.4

5.9

Back Up Heating Capacity

dB(A)

0.7

0.9

0.6

0.9

1.4

EER*2

Cool

4.22

3.40

3.69

3.21

2.81

COP*2

Heat

4.63

4.00

4.10

4.00

3.75

Sound Preassure Level*3 (Cool)

dB(A)

45

46

46

49

57

Sound Power Level (Cool)

dB

62

62

62

65

68

Dimensions (WxHxD)

mm

890x645x290

890x645x290

890x645x290

890x800x320

890x800x320

Net Weight

kg

51

51

53

64

70

Pipe Diameter

Liquid Side

inch

1/4 x 2

1/4 x 2

1/4 x 3

1/4 x 4

1/4 x 4

Gas Side

inch

3/8 x 2

3/8 x 2

3/8 x 3

3/8 x 4

3/8 x 3, 3/8 or 1/2 x 1

Min. – Max. Pipe Length (per indoor unit)

m

3 – 25

3 – 25

3 – 25

3 – 20

3 – 20

Maximum Length (total)

m

40

40

50

50

50

Maximum Chargeless Length (total)

m

25

25

30

40

50

Maximum Height Difference

m

10

10

10

10

10

Refrigerant/GWP*6

kgCO

2

eq.

R410A (1975)

R410A (1975)

R410A (1975)

R410A (1975)

R410A (1975)

Operating Range (Outdoor)

Cool

°C

-10 – 43

-10 – 43

21 – 43

21 – 43

21 – 43

Heat

°C

-15 – 24

-15 – 24

-15 – 24

-15 – 24

-15 – 24

Indoor Units

Wall Mounted

Floor Standing

Floor/Ceiling

Model

AY-XPM7/XPC9/XPC12PHR

AY-XPC7/9/12JR

AY-XPM7/9/12FR

AY-XPC18LR

GS-XPM9/12/18FGR

GS-XPM7/9/12FR

Sound Pressure Level (Hi/Lo)*3 (Cool)

dB(A)

7PHR:3/26, 9PHR:39/26,

12PHR:42/27

7JR: 36/26, 9JR: 37/26,

12JR: 40/27

7FR: 37/28, 9FR: 39/28,

12FR: 40/29

43/39

9FGR: 38/25, 12FGR: 40/26,

18FGR: 44/35

7FR: 34/27, 9FR: 38/29,

12FR: 39/30

Sound Power Level (Cool) (Hi)

dB

7PHR:53, 9PHR:54, 12PHR:56

7JR: 51, 9JR: 52, 12JR: 56

7FR: 52, 9FR: 54, 12FR: 56

58

9FGR: 53, 12FGR: 54, 18FGR: 60

7FR: 47, 9FR: 52, 12FR: 52

Airflow Volume (Cool) (Hi)

m3/min

7PHR:9.4, 9PHR:9.7, 12PHR:10.8

7JR: 8.9, 9JR: 9.1, 12JR: 10.5

7FR: 8.0, 9FR: 8.6, 12FR: 9.8

14.4

9FGR: 9.3, 12FGR: 10.6, 18FGR: 14.2

7FR: 7.5, 9FR: 8.7, 12FR: 10.4

Dimensions

W

mm

920

790

790

1,040

750

1,025

H

290

278

278

325

670

680

D

240

198

198

222

235

212

Net Weight

kg

10

10

10

12

17

31

Operating

status

Indoor unit

combination

Cooling capacity (kW)

Heating capacity (kW)

Power input (W)

Rating (Min. – Max.)

A

B

A

B

Rating

(Min. – Max.)

A

B

Rating

(Min. – Max.)

Cool

Heat

2-indoor

unit

operation

12

9

2.17

1.63

3.8 (1.8 – 4.3)

2.51

1.89

4.4 (1.9 – 5.4) 900 (350 – 1,160) 950 (370 – 1,300)

12

7

2.40

1.40

3.8 (1.8 – 4.3)

2.78

1.62

4.4 (1.9 – 5.4) 900 (350 – 1,160) 950 (370 – 1,300)

9

9

1.90

1.90

3.8 (1.8 – 4.3)

2.20

2.20

4.4 (1.9 – 5.4) 900 (350 – 1,160) 950 (370 – 1,300)

9

7

2.14

1.66

3.8 (1.8 – 4.3)

2.48

1.93

4.4 (1.9 – 5.4) 900 (350 – 1,160) 950 (370 – 1,300)

Operating

status

Indoor unit

combination

Cooling capacity (kW)

Heating capacity (kW)

Power input (W)

Rating (Min. – Max.)

A

B

A

B

Rating

(Min. – Max.)

A

B

Rating

(Min. – Max.)

Cool

Heat

2-indoor

unit

operation

12

12

2.60

2.60

5.2 (1.8 – 6.0)

2.90

2.90

5.8 (1.9 – 7.3) 1,530 (350 – 2,050) 1,450 (370 – 2,100)

12

9

2.97

2.23

5.2 (1.8 – 6.0)

3.31

2.49

5.8 (1.9 – 7.3) 1,530 (350 – 2,050) 1,450 (370 – 2,100)

12

7

3.28

1.92

5.2 (1.8 – 6.0)

3.66

2.14

5.8 (1.9 – 7.3) 1,530 (350 – 2,050) 1,450 (370 – 2,100)

9

9

2.60

2.60

5.2 (1.8 – 6.0)

2.90

2.90

5.8 (1.9 – 7.3) 1,530 (350 – 2,050) 1,450 (370 – 2,100)

9

7

2.64

2.06

4.7 (1.8 – 5.6)

3.04

2.36

5.4 (1.9 – 7.0) 1,340 (350 – 1,830) 1,310 (370 – 2,030)

Operating

status

Indoor unit

combination

Cooling capacity (kW)

Heating capacity (kW)

Power input (W)

Rating (Min. – Max.)

A

B

C

A

B

C

Rating

(Min. – Max.)

A

B

C

Rating

(Min. – Max.)

Cool

Heat

3-indoor

unit

operation

12

9

9

2.08 1.56 1.56 5.2 (2.2 – 7.2) 2.72 2.04 2.04 6.8 (2.2 – 8.4) 1,410 (430 – 2,560) 1,660 (420 – 2,480)

12

9

7

2.23 1.67 1.30 5.2 (2.2 – 7.2) 2.91 2.19 1.70 6.8 (2.2 – 8.4) 1,410 (430 – 2,560) 1,660 (420 – 2,480)

12

7

7

2.40 1.40 1.40 5.2 (2.2 – 7.2) 3.14 1.83 1.83 6.8 (2.2 – 8.4) 1,410 (430 – 2,560) 1,660 (420 – 2,480)

9

9

9

1.73 1.73 1.73 5.2 (2.2 – 7.2) 2.27 2.27 2.27 6.8 (2.2 – 8.4) 1,410 (430 – 2,560) 1,660 (420 – 2,480)

9

9

7

1.87 1.87 1.46 5.2 (2.2 – 7.2) 2.45 2.45 1.90 6.8 (2.2 – 8.4) 1,410 (430 – 2,560) 1,660 (420 – 2,480)

9

7

7

2.03 1.58 1.58 5.2 (2.2 – 7.2) 2.66 2.07 2.07 6.8 (2.2 – 8.4) 1,410 (430 – 2,560) 1,660 (420 – 2,480)

7

7

7

1.73 1.73 1.73 5.2 (2.2 – 7.0) 2.27 2.27 2.27 6.8 (2.2 – 8.4) 1,410 (430 – 2,560) 1,660 (420 – 2,480)

2-indoor unit

operation

12

12

2.50 2.50

5.0 (1.9 – 6.5) 3.35 3.35

6.7 (1.6 – 8.0) 1,400 (350 – 2,400) 1,970 (380 – 2,670)

12

9

*

2.86 2.14

*

5.0 (1.9 – 6.5) 3.83 2.87

*

6.7 (1.6 – 8.0) 1,400 (350 – 2,400) 1,970 (380 – 2,670)

Operating

status

Indoor unit

combination

Cooling capacity (kW)

Heating capacity (kW)

Power input (W)

Rating (Min. – Max.)

A

B

C

A

B

C

Rating

(Min. – Max.)

A

B

C

Rating

(Min. – Max.)

Cool

Heat

2-indoor

unit

operation

12

7

*

3.16 1.84

*

5.0 (1.9 – 6.4) 4.17 2.43

*

6.6 (1.6 –8.0) 1,400 (350 – 2,380) 1,970 (380 – 2,670)

9

9

*

2.45 2.45

*

4.9 (1.9 – 6.2) 3.10 3.10

*

6.2 (1.6 – 8.0) 1,380 (350 – 2,200) 1,800 (380 – 2.670)

9

7

*

2.53 1.97

*

4.5 (1.9 – 5.7) 3.15 2.45

*

5.6 (1.6 – 7.3) 1,190 (350 – 1,870) 1,550 (380 – 2,310)

7

7

*

2.00 2.00

*

4.0 (1.9 – 5.2) 2.50 2.50

*

5.0 (1.6 – 6.4) 1,000 (350 – 1,550) 1,320 (380 – 1,910)

1-indoor

unit

operation

12

*

*

3.40

*

*

3.4 (1.4 – 4.0) 4.00

*

*

4.0 (1.1 – 5.2) 950 (320 – 1,350) 1,400 (330 – 2,150)

9

*

*

2.60

*

*

2.6 (1.4 – 3.3) 3.00

*

*

3.0 (1.1 – 4.2)

680 (320 – 950)

970 (330 – 1,570)

7

*

*

2.00

*

*

2.0 (1.4 – 2.7) 2.40

*

*

2.4 (1.1 – 3.3)

520 (320 – 710)

720 (330 – 1,130)

Operating status

Indoor unit

combination

Cooling capacity (kW)

Heating capacity (kW)

Power input (W)

Rating (Min. – Max.)

A

B

A

B

Rating

(Min. – Max.)

A

B

Rating

(Min. – Max.)

Cool

Heat

2-indoor unit operation

7

7

1.90

1.90

3.8 (1.8 – 4.3)

2.20

2.20

4.4 (1.9 – 5.4) 900 (350 – 1,160) 950 (370 – 1,300)

1-indoor unit

operation

12

*

3.40

OFF

3.4 (1.4 – 3.3)

3.90

OFF

3.9 (1.2 – 4.6) 910 (320 – 1,320) 1,140 (320 – 1,570)

9

*

2.60

OFF

2.6 (1.4 – 3.3)

3.00

OFF

3.0 (1.2 – 4.2)

660 (320 – 920)

830 (330 – 1,400)

7

*

2.00

OFF

2.0 (1.4 – 2.7)

2.40

OFF

2.4 (1.2 – 3.3)

510 (320 –700)

680 (320 – 1,010)

Operating status

Indoor unit

combination

Cooling capacity (kW)

Heating capacity (kW)

Power input (W)

Rating (Min. – Max.)

A

B

A

B

Rating

(Min. – Max.)

A

B

Rating

(Min. – Max.)

Cool

Heat

2-indoor unit operation

7

7

2.10

2.10

4.2 (1.8 – 5.2)

2.50

2.50

5.0 (1.9 – 6.3) 1,120 (350 – 1,540) 1,170 (370 – 1,700)

1-indoor unit

operation

12

*

3.40

*

3.4 (1.4 – 4.0)

4.00

*

4.0 (1.2 – 5.2) 950 (320 – 1,350) 1,240 (320 – 1,900)

9

*

2.60

*

2.6 (1.4 – 3.3)

3.00

*

3.0 (1.2 – 4.2)

680 (320 – 950)

830 (330 – 1,440)

7

*

2.00

*

2.0 (1.4 – 2.7)

2.40

*

2.4 (1.2 – 3.3)

510 (320 – 700)

680 (320 –1,050)

*1 According to EN14511. *2 According to EN14825. *3 Sound pressure level is measured according to JIS C 9612.
*4 7: AY-XPM7PHR, AY-XPC7JR, AY-XPM7FR, GS-XPM7FR; 9: AY-XPC9PHR, AY-XPC9JR, AY-XPM9FR, GS-XPM9FR, GS-XPM9FGR
*5 Energy consumption “XYZ” kWh per year, based on standardtest results. Actual energy consumption will depend on how theappliance is used and where it is located.
*6 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leakedto the atmosphere.

This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher

than 1 kg of CO

2

, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.

* When the Multi inverter type is used to operate two or more indoor units simultaneously, the capacity
of each indoor unit may be lower than that when operating only one indoor unit. Be sure to refer to the
capacity table to select the appropriate models.

Indoor

units

AY-XPM7PHR, AY-XPC7JR, AY-XPM7FR, GS-XPM7FR
AY-XPC9PHR, AY-XPC9JR, AY-XPM9FR, GS-XPM9FR, GS-XPM9FGR
AY-XPC12PHR, AY-XPC12JR, AY-XPM12FR, GS-XPM12FR, GS-XPM12FGR
AY-XPC18LR, GS-XPM18FGR

7
9

12
18

* When connected indoor unit is not in operation.

* When connected indoor unit is not in operation.

* When connected indoor unit is not in operation.

INVERTER

MULTI TYPE

Advertising