Inverter, Ay-xpc18/xp24lr, Single / multi type – Sharp AY-XP9RMR-AE-X9RMR User Manual
Page 12: R410a, Deluxe, Ae-x18lr ae-x24lr
11
Deluxe
AY-XPC18/XP24LR
Specifi cation
Features
Cool/Dry/Heat
Spot Air
Area–specifi c
comfort
Outdoor unit
R410A
• Spot Air function
• Coanda Airfl ow System
• Can be used singly or in a multi split system
(for AY-XPC18LR)
Push the button to cycle through
and choose from six areas.
* For the AY-XPC18LR model only.
Model
AY-XPC18LR
5.00 (1.40 – 5.70)
5.70 (1.10 – 8.00)
6.6
3.8
Cooling operation
Heating operation
Capacity (kW)
(Min. – Max.)
Capacity (kW)
(Min. – Max.)
SEER
SCOP
AY-XP24LR
7.00 (1.50 – 8.00)
7.50 (1.10 – 9.50)
5.9
4.0
A
+A
++A
+A
Model
Indoor
AY-XPC18LR
AY-XP24LR
Outdoor
AE-X18LR
AE-X24LR
Preformance*1
Cooling
Energy Effi ciency Class
A++
A+
SEER
6.6
5.9
Pdesign
kW
5.0
7.0
Capacity (Min. – Max.)
kW
5.00 (1.40 – 5.70)
7.00 (1.50 – 8.00)
Input (Min. – Max.)
W
1,470 (260 – 1,890)
2,160 (260 – 2,990)
Annual electricity consumption*2
kWh/a
264
413
Heating
(Average
Climate)
Energy Effi ciency Class
A
A+
SCOP
3.8
4.0
Pdesign
kW
5.7
6.7
Capacity (Min. – Max.)
kW
5.70 (1.10 – 8.00)
7.50 (1.10 – 9.50)
Input (Min. – Max.)
W
1,510 (240 – 2,380)
2,015 (240 – 2,830)
Annual electricity consumption*2
kWh/a
2,064
2,323
Nominal Effi ciency*3
EER
3.40
3.24
COP
3.77
3.72
Nominal Current*3
Cooling
A
6.6
9.6
Heating
A
6.8
8.9
Sound Pressure Level*4 (Cool)
Indoor (Hi/Lo)
dB(A)
43/33
47/35
Outdoor
db(A)
49
53
Sound Power Level (Cool)
Indoor (Hi)
58
63
Outdoor
62
66
Airfl ow Volume (Hi, Cool)
m3/min
14.4
18.4
Operation Range (Outdooor)
Coolong
°C
-10 – 46
-10 – 46
Heating
°C
-15 – 24
-15 – 24
Model
Indoor
AY-XPC18LR
AY-XP24LR
Outdoor
AE-X18LR
AE-X24LR
Power Supply
Outdoor
V/Phase/Hz 220 – 240/single/50 220 – 240/single/50
Dimensions
Indoor (WxHxD)
mm
1,040x325x222
1,040x325x222
Outdoor (WxHxD)
mm
850x710x330
850x710x330
Weight
Indoor
kg
12
13
Outdoor
kg
49
53
Min. – Max. Pipe Lenght
m
1 – 20
1 – 30
Max. Height Difference
m
10
10
Max. Chargless Lenght
m
10
10
Pipe Diameter
Liquid Side
inch
1/4
1/4
Gas Side
inch
1/2
5/8
Refrigerant (GWP*5)
kgCO
2
eq.
R410A (1975)
R410A (1975)
*1 According to EN14825
*2 Energy consumption “XYZ” kWh per year, based on standard test results. Actual energy
consumption will depend on how the appliance is used and where it is located.
*3 According to EN14511
*4 Sound pressure level is measured according to JIS C 9612.
*5 Refrigerant leakage contributes to climate change. Refrigerant with lower global
warming potential (GWP) would contribute less to global warming than a refrigerant
with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fl uid
with a GWP equal to 1975. This means that if 1 kg of this refrigerant fl uid would be leaked
to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg
of CO
2
, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
AE-X18LR AE-X24LR
Lid opened
Spot Air
ON
INVERTER
SINGLE / MULTI TYPE
Spot Air
OFF
- AY-XPC9JR - AE-X9JR AY-X12RSR-AE-X12RSR AY-XP9LSR - AE-X9LSR CV-P09FR AY-XPC12RR-AE-X12RR AY-XPM7PHR AE-XM30GR AY-XP12RMR-AE-X12RMR AY-XPC12JR - AEX12JR AE-XM24HR AY-X12PSR - AE-X12PSR AY-XPC9RR-AE-X9RR AE-X3M18JR AY-XPC12PHR - AE-X12PHR AY-XPC18LR - AE-X18LR AY-X9PSR - AE-X9PSR AY-X9RSR-AE-X9RSR CV-P10PR AY-XP24LR - AE-X24LR AY-XP12LSR - AE-X12LSR AY-XPC7JR - AE-X7JR AY-XPC9PHR - AE-X9PHR