Deluxe

AY-XPC18/XP24LR

Specifi cation

Features

Cool/Dry/Heat

Spot Air
Area–specifi c
comfort

Outdoor unit

R410A

• Spot Air function
• Coanda Airfl ow System
• Can be used singly or in a multi split system

(for AY-XPC18LR)

Push the button to cycle through
and choose from six areas.

* For the AY-XPC18LR model only.

Model

AY-XPC18LR

5.00 (1.40 – 5.70)

5.70 (1.10 – 8.00)

6.6

3.8

Cooling operation

Heating operation

Capacity (kW)

(Min. – Max.)

Capacity (kW)

(Min. – Max.)

SEER

SCOP

AY-XP24LR

7.00 (1.50 – 8.00)

7.50 (1.10 – 9.50)

5.9

4.0

A

+A

++A

+A

Model

Indoor

AY-XPC18LR

AY-XP24LR

Outdoor

AE-X18LR

AE-X24LR

Preformance*1

Cooling

Energy Effi ciency Class

A++

A+

SEER

6.6

5.9

Pdesign

kW

5.0

7.0

Capacity (Min. – Max.)

kW

5.00 (1.40 – 5.70)

7.00 (1.50 – 8.00)

Input (Min. – Max.)

W

1,470 (260 – 1,890)

2,160 (260 – 2,990)

Annual electricity consumption*2

kWh/a

264

413

Heating
(Average
Climate)

Energy Effi ciency Class

A

A+

SCOP

3.8

4.0

Pdesign

kW

5.7

6.7

Capacity (Min. – Max.)

kW

5.70 (1.10 – 8.00)

7.50 (1.10 – 9.50)

Input (Min. – Max.)

W

1,510 (240 – 2,380)

2,015 (240 – 2,830)

Annual electricity consumption*2

kWh/a

2,064

2,323

Nominal Effi ciency*3

EER

3.40

3.24

COP

3.77

3.72

Nominal Current*3

Cooling

A

6.6

9.6

Heating

A

6.8

8.9

Sound Pressure Level*4 (Cool)

Indoor (Hi/Lo)

dB(A)

43/33

47/35

Outdoor

db(A)

49

53

Sound Power Level (Cool)

Indoor (Hi)

58

63

Outdoor

62

66

Airfl ow Volume (Hi, Cool)

m3/min

14.4

18.4

Operation Range (Outdooor)

Coolong

°C

-10 – 46

-10 – 46

Heating

°C

-15 – 24

-15 – 24

Model

Indoor

AY-XPC18LR

AY-XP24LR

Outdoor

AE-X18LR

AE-X24LR

Power Supply

Outdoor

V/Phase/Hz 220 – 240/single/50 220 – 240/single/50

Dimensions

Indoor (WxHxD)

mm

1,040x325x222

1,040x325x222

Outdoor (WxHxD)

mm

850x710x330

850x710x330

Weight

Indoor

kg

12

13

Outdoor

kg

49

53

Min. – Max. Pipe Lenght

m

1 – 20

1 – 30

Max. Height Difference

m

10

10

Max. Chargless Lenght

m

10

10

Pipe Diameter

Liquid Side

inch

1/4

1/4

Gas Side

inch

1/2

5/8

Refrigerant (GWP*5)

kgCO

2

eq.

R410A (1975)

R410A (1975)

*1 According to EN14825
*2 Energy consumption “XYZ” kWh per year, based on standard test results. Actual energy

consumption will depend on how the appliance is used and where it is located.

*3 According to EN14511
*4 Sound pressure level is measured according to JIS C 9612.
*5 Refrigerant leakage contributes to climate change. Refrigerant with lower global
warming potential (GWP) would contribute less to global warming than a refrigerant

with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fl uid

with a GWP equal to 1975. This means that if 1 kg of this refrigerant fl uid would be leaked

to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg

of CO

2

, over a period of 100 years. Never try to interfere with the refrigerant circuit

yourself or disassemble the product yourself and always ask a professional.

AE-X18LR AE-X24LR

Lid opened

Spot Air

ON

INVERTER

SINGLE / MULTI TYPE

Spot Air

OFF

Advertising