Sharp’s multi-split air conditioning systems allow you to

combine up to four indoor

units with a single outdoor unit. The indoor units can be wall

mounted types, fl oor/ceiling types,

or fl oor standing types. This wide-ranging choice of indoor

units offers you more fl exible

coordination for each room.

* See the specifi cation table for multi type indoor and outdoor units on page 17.

* Representative connection (7+7+7)

*1 AE-XM24HR Representative connection (7+7+7+7)
*2 AE-XM30GR Representative connection (9+7+7+7)

* At least two indoor units must be connected.
* See the capacity table on page 17 for permissible combinations.

* At least three indoor units must be connected.
* See the capacity table on page 18 for permissible combinations.

for indoor units

Outdoor unit lineup

12

18

Example of indoor unit combinations

Example of indoor unit combinations

AE-XM24HR

AE-XM30GR

AE-X3M18JR

4 indoor units

3 indoor units

Outdoor Unit

Indoor Unit

Cooling Operation

Heating Operation

Capacity (kW)

(Min. – Max.)

SEER

Capacity (kW)

(Min. – Max.)

SCOP

AE-X3M18JR

Cool/Heat/Dry

12 + 7 + 7

5.2 (2.2 – 7.2)

6.0*

6.8 (2.2 – 8.4)

4.1*

9 + 9 + 7

5.2 (2.2 – 7.2)

6.8 (2.2 – 8.4)

9 + 7 + 7

5.2 (2.2 – 7.2)

6.8 (2.2 – 8.4)

7 + 7 + 7

5.2 (2.2 – 7.0)

6.8 (2.2 – 8.4)

Outdoor Unit

Indoor Unit

Cooling Operation

Heating Operation

Capacity (kW)

(Min. – Max.)

SEER

Capacity (kW)

(Min. – Max.)

SCOP

AE-XM24HR

Cool/Heat/Dry

12 + 7 + 7 + 7

7.00 (3.00 – 8.20)

6.2

*1

8.00 (3.00 – 9.20)

4.3

*1

9 + 9 + 7 + 7

7.00 (3.00 – 8.20)

8.00 (3.00 – 9.20)

9 + 7 + 7 + 7

7.00 (3.00 – 8.20)

8.00 (3.00 – 9.20)

7 + 7 + 7 + 7

7.00 (3.00 – 8.20)

8.00 (3.00 – 9.20)

AE-XM30GR

Cool/Heat/Dry

18 + 7 + 7 + 7

8.40 (4.30 – 9.00)

5.2

*2

9.00 (4.40 – 10.60)

3.9

*2

12 + 7 + 7 + 7

8.40 (4.30 – 9.00)

9.00 (4.40 – 10.60)

9 + 9 + 7 + 7

8.40 (4.30 – 9.00)

9.00 (4.40 – 10.60)

9 + 7+ 7 + 7

8.40 (4.30 – 9.00)

9.00 (4.40 – 10.60)

7 + 7 + 7 + 7

8.40 (4.30 – 9.00)

8.50 (4.40 – 9.80)

3 ROOMS

4 ROOMS

R410A

R410A

Connection indoor units

Wall mounted

AY-XPM7FR

Wall mounted

AY-XPM9FR

Wall mounted

AY-XPM12FR

Wall mounted

AY-XPC7JR

Wall mounted

AY-XPC9JR

Wall mounted

AY-XPC12JR

Wall mounted

AY-XPM7PHR

NEW

Wall mounted

AY-XPC9PHR

NEW

Wall mounted

AY-XPC12PHR

Wall mounted

AY-XPC18LR

Floor standing

GS-XPM9FGR

Floor standing

GS-XPM12FGR

Floor standing

GS-XPM18FGR

For AE-XM30GR only*

Floor/ceiling

GS-XPM7FR

Floor/ceiling

GS-XPM9FR

Floor/ceiling

GS-XPM12FR

NEW

GS-XPC18PR

INVERTER