13 Configuration

168

13.13.1 Binary linking

Setup dialog

Parameter

Start at text

Parameter

Selection/settings

Description

Start at text

1 to 64

This parameter acts as a starting point
for binary linking. If binary linking is
active for a batch text, one of the 128
internal batch texts of the device can be
added to a current batch protocol from
the position "Start at text".

2

0

to 2

5

Inactive

Digital selector

Depending on the configuration, the
binary linking can be used to integrate
up to 64 different texts into the batch
report using the digital signals.

There is a total of 128 batch texts that
are available and can be defined in the
setup program. The batch text used is
composed of the "Start at text" parame-
ter and the "Binary linking".

NOTE!
Batch text used = Start at text + Binary linking
The user can configure the batch texts using the setup program.