Commissioning

Basic settings

Motor selection list

6

6.5

6.5.5

l

6.5−9

EDSVS9332P EN 5.0−07/2013

Temperature sensor

Motor type

C0090

U

r

[V]

C0089

f

r

[Hz]

C0088

I

r

[A]

C0087

n

r

[rpm]

C0081

P

r

[kW]

Lenze type

1

0

225

30kW−ASM−50

˘

30.00

1470

52.0

50

400

Asynchronous

inverter motor

(star connection)

˘

226

37kW−ASM−50

˘

37.00

1470

66.0

227

45kW−ASM−50

˘

45.00

1480

82.0

228

55kW−ASM−50

˘

55.00

1480

93.0

229

75kW−ASM−50

˘

75.00

1480

132.0

250

DXRAXX071−12−87

DXRAXX071−12

0.43

2525

1.5

87

400

Asynchronous

inverter motor

(delta connection)

Thermal contact

251

DXRAXX071−22−87

DXRAXX071−22

0.64

2515

2.0

252

DXRAXX080−12−87

DXRAXX080−12

0.95

2515

2.9

253

DXRAXX080−22−87

DXRAXX080−22

1.3

2525

4.0

254

DXRAXX090−12−87

DXRAXX090−12

2.0

2535

4.7

255

DXRAXX090−32−87

DXRAXX090−32

2.7

2530

6.2

256

DXRAXX100−22−87

DXRAXX100−22

3.9

2535

8.3

257

DXRAXX100−32−87

DXRAXX100−32

5.35

2530

11.4

258

DXRAXX112−12−87

DXRAXX112−12

7.10

2545

14.3

259

DXRAXX132−12−87

DXRAXX132−12

9.7

2555

19.1

260

DXRAXX132−22−87

DXRAXX132−22

13.2

2555

25.4

261

DXRAXX160−12−87

DXRAXX160−12

19.3

2565

36.5

262

DXRAXX160−22−87

DXRAXX160−22

26.4

2565

48.4

263

DXRAXX180−12−87

DXRAXX180−12

32.4

2575

57.8

264

DXRAXX180−22−87

DXRAXX180−22

38.7

2560

67.4

265

30kW−ASM−87

˘

52.00

2546

90.0

87

400

Asynchronous

inverter motor

(delta connection)

˘

266

37kW−ASM−87

˘

64.00

2546

114.0

267

45kW−ASM−87

˘

78.00

2563

142.0

268

55kW−ASM−87

˘

95.00

2563

161.0

269

75kW−ASM−87

˘

130.00

2563

228.0

The motors listed in the Motor nameplate data" table column are not
included in Global Drive Control (GDC) and in the controller software.

1. Enter the corresponding value of column "C86" in C0086.

2. Compare the motor data codes with the table values.

– If necessary, adapt the values in the controller to the table values.

3. Optimise the dynamic performance of your machine via codes C0070

and C0071 if necessary.

Motor nameplate data

Motor data

Field

C0086

C0022

C0081

C0084

C0085

C0087

C0088

C0089

C0090

C0091

C0070

C0071

C0075

C0076

C86

Type

Imax

[A]

P

r

[kW]

R

s

[

W]

L

s

[mH]

n

r

[rpm]

I

r

[A]

f

r

[Hz]

U

r

[V]

cos

j

V

pn

T

nn

V

pi

T

ni

410

MDXMAXM−071−12

210

1.23

0.25

35.80

116.80

1400

0.82

50

400

0.70

6

300

1.5

10

411

MDXMAXM−071−32

211

1.80

0.37

27.00

112.70

1400

1.20

50

400

0.71

6

300

1.5

10

412

MDXMAXM−080−12

212

2.40

0.55

16.30

78.60

1400

1.60

50

400

0.72

6

300

1.5

10

413

MDXMAXM−080−32

213

3.00

0.75

11.20

59.30

1380

2.00

50

400

0.76

6

300

1.5

10

414

MDXMAXM−090−12

214

3.90

1.10

9.14

41.80

1410

2.60

50

400

0.80

6

300

1.5

10

415

MDXMAXM−090−32

215

5.25

1.50

5.10

27.70

1420

3.50

50

400

0.80

6

300

1.5

10

416

MDXMAXM−100−12

216

8.40

2.20

2.96

18.20

1400

5.60

50

400

0.78

6

300

1.5

10

417

MDXMAXM−100−32

217

10.95

3.00

2.20

13.40

1400

7.30

50

400

0.81

6

300

1.5

10

418

MDXMAXM−112−22

218

12.75

4.00

1.50

10.80

1430

8.50

50

400

0.85

6

300

1.5

10

440

MDXMAXM−071−12

250

2.10

0.43

35.8

116.80

2510

1.40

87

400

0.70

6

300

1.5

10

441

MDXMAXM−071−32

251

3.15

0.64

27.0

112.70

2510

2.10

87

400

0.71

6

300

1.5

10

442

MDXMAXM−080−12

252

4.20

0.95

16.3

78.60

2510

2.80

87

400

0.72

6

300

1.5

10

443

MDXMAXM−080−32

253

5.25

1.30

11.2

59.30

2490

3.50

87

400

0.76

6

300

1.5

10

444

MDXMAXM−090−12

254

6.75

2.00

9.14

41.80

2520

4.50

87

400

0.80

6

300

1.5

10

445

MDXMAXM−090−32

255

9.15

2.70

5.1

27.70

2530

6.10

87

400

0.78

6

300

1.5

10

Asynchronous motor
reference list