Configuration

Basic configurations

8

8.5

l

8.5−2

EDSVS9332P EN 5.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0005

s

SIGNAL CFG

20000

Signal configuration
Predefined basic configurations

^ 8.5−1

0

COMMON

Changed basic configuration

100

Empty

All internal links are deleted

1000

Speed control

20000

Standard absolute positioning

Meaning of the digits:

l

2xxxx: Positioning control

l

2xxxx: Positioning mode
– 0: Positioning via home

position

– 2: Positioning via position

switch points and with
teach function

– 6: External path control

l

2xxxx: Positioning type
– 0: Absolute positioning
– 2: Relative positioning

l

2xxxx: Voltage source for
the control terminals
– 0: External supply voltage
– 1: Internal supply voltage

l

2xxxx: Device control
– 0: Via control terminals
– 1: Via LECOM A/B/LI
– 3: Via AIF (INTERBUS,

Profibus)

– 5: Via system bus (CAN)

20003

Absolute/AIF

20010

Absolute/supply

20013

Absolute/supply/AIF

20200

Relative positioning

20203

Relative/AIF

20210

Relative/supply

20213

Relative/supply/AIF

22000

Absolute/switching pt.

22003

Absolute/switching pt./AIF

22010

Absolute/switching pt./supply

22013

Absolute/switching pt./supply/AIF

22200

Relative/switching pt.

22203

Relative/switching pt./AIF

22210

Relative/switching pt./supply

22213

Relative/switching pt./supply/AIF

26000

Interpolated set pos. selection

26010

Interpolated set pos. sel./supply

C0006

s

OP MODE

à

Motor control mode

2

Servo async. Y asynchronous motor,
star

à

Depends on C0086

l

Change of C0086 resets
value to the assigned
default setting

l

Change of C0006 sets C0086
= 0!

3

Servo PM−SM Y PM synchronous
motor, star

22

Servo asyn asychronous motor, delta

C0009 LECOM

ADDRESS

1

1

{1}

99 LECOM unit address

Number of the node for
operation via interface

l

10, 20, ..., 90 reserved for
broadcast communication to
device groups for RS232,
RS485, optical fibre

C0011 NMAX

3000

500

{1 rpm}

16000 Max. speed N

max

Reference value for the
absolute and relative setpoint
selection for the acceleration
and deceleration times

l

For parameter setting via
interface:
– Greater changes in one

step should only be made
when the controller is
inhibited

C0012 TIR (ACC)

0.000

0.000

{0.001 s}

999.900 Acceleration time T

ir

for the

main setpoint of NSET (relating
to speed variation 0 ... n

max

)

C0013 TIF (DEC)

0.000

0.000

{0.001 s}

999.900 Deceleration time T

if

for the

main setpoint of NSET (relating
to speed variation n

max ...

0)