6.2 Function test
Caution !

Apply armature voltage only when excitation voltage is

applied!

When the voltage is applied without an excitation voltage

being applied to the motor, the motor may be destroyed

due to overspeed, i.e. the motor speed may rise until the

rotor is destroyed.

¯

Commission the drives and check all

individual functions, such as

-- torque behaviour and current

consumption

-- braking of the attached brake
-- output signal of the feedback system

¯

in case of malfunctions or interferences:

trouble--shooting according to chapter 6.4.

6.3 Inspection
¯

We recommend to inspect drives in

operation every 50 operating hours.

Observe:

-- loud noises
-- excessive surface temperatures
-- oily drive parts or leakages
-- changed speeds etc.

¯

In case of irregularities:

see trouble--shooting chapter 6.4.