37 l_convap_1, 37 l_convap_1 5, L_convap_1 – Lenze 8400 TopLine User Manual
Page 1435: 19 function library

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1435
19
Function library
19.1
Function blocks
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
19.1.37
L_ConvAP_1
This FB converts an analog value into a position.
Inputs
Outputs
Parameter
Function
Identifier
Data type
Information/possible settings
nIn_a
INT
Input value
• Scaling: 16384 ≡ 100 %
Identifier
Data type
Value/meaning
dnOut_p
DINT
Output signal
• Internal limitation to ±2
31
-1 (±2147483647)
Parameter
Possible settings
Info
-32767
32767 Counter
• Lenze setting: 1
-32767
32767 Denominator
• Lenze setting: 1
Note!
Conversion is remainder considered.
/B&RQY$3B
Q,QBD
GQ2XWBS
&
&
dnOut_p
nIn_a C01045/1
C01045/2
-------------------------
⋅
=