159 l_signalmonitor_a, 159 l_signalmonitor_a 6, L_signalmonitor_a – Lenze 8400 TopLine User Manual
Page 1666: 19 function library

19
Function library
19.1
Function blocks
1666
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
19.1.159
L_SignalMonitor_a
This FB outputs four analog signals which can be selected from a list of analog output signals of all
function blocks provided in the device.
• Offset and gain of the source signals are adjustable.
Outputs
Parameter
Identifier
Data type
Value/meaning
nOut1_a
INT
Output signal
• Internal limitation to ±32767
nOut2_a
INT
Output signal
• Internal limitation to ±32767
nOut3_a
INT
Output signal
• Internal limitation to ±32767
nOut4_a
INT
Output signal
• Internal limitation to ±32767
Parameter
Possible settings
Info
...
selection list - analog signals
Selection of the signal sources for
nOut1_a ... nOut4_a
-199.99
%
+199.99 Offset
-199.99
%
+199.99 Gain
/B6LJQDO0RQLWRUBD
Q2XWBD
&
&
&
Q2XWBD
&
&
&
Q2XWBD
&
&
&
Q2XWBD
&
&
&