3 terminals 11, Terminals 11, 8technology applications – Lenze 8400 TopLine User Manual
Page 474

8
Technology applications
8.3
TA "actuating drive speed (AC Drive Profile)"
474
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.3.4.3
Terminals 11
Connection
Assignment
Connection
Assignment
X101/NC-NO
LA_NCtrl.bDriveFail
X5/RFR
LA_NCtrl.bFailReset
X3/A1U
LA_NCtrl.nAuxSetValue_a *
X5/DI1
LA_NCtrl.bSetSpeedCcw
X3/A1I
-
X5/DI2
LA_NCtrl.bSetDCBrake
X3/A2U
-
X5/DI3
LA_NCtrl.bMPotUp
X3/A2I
-
X5/DI4
LA_NCtrl.bMPotDown
X3/O1U
LA_NCtrl.nMotorSpeedAct_a *
X5/DI5
-
X3/O1I
-
X5/DI6
-
X3/O2U
-
X5/DI7
-
X3/O2I
-
* 10 V ≡ 100 % reference speed (
X107/BD1
-
X4/DO1
LA_NCtrl.bDriveReady
X107/BD2
-
X4/DO2
-
X4/DO3
-
X4
24B
24O
GB
DO1
BD2
DO3
GO
BD1
DO2
A2I
AR
COM
A1U
NC
A2U
A1I
NO
X3
DI3
DI2
DI4
DI5
DI6
DI7
GI
24I
DI1
RFR
GA
O1U
O1I
O2U
O2I
X101
24E
+
=
CG
CL
CH
X1
X5
X107
Controller enable / reset error
Direction of rotation Ccw
DC brake active
Speed higher
Speed lower
Motor
potentiometer
External
supply
24 V DC
DriveFail
DriveReady
Actual speed value
Speed mode:
Torque mode:
Speed setpoint
Torque setpoint