9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

4

Parameter setting & configuration

Note!

The electrical shaft can be implemented with a bus system such as system bus

(CAN) or Ethernet Powerlink or via digital frequency transmission.
With regard to the configuration of the digital frequency extension module in

the controller, two variants of technology applications are available in the

»Engineer« application catalog.
• In the TA variant "Synchronism with mark synchronisation" the configuration

of a digital frequency extension module is expected. Therefore, the TA can

provide the function of the electrical shaft either via digital frequency

transmission and via a bus system.

• In the TA variant "Synchronism with mark synchronisation MotionBus" the

configuration of a digital frequency extension module is not included and

corresponding interfaces are not available in the TA. Thus the function of the

electrical shaft with this TA can only be provided via a bus system.