EDS94TA10040xxxx EN 1.1 - 10/2008

L

57

9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

Parameterisable function blocks

4.14.5

CompareTPDiffTool

4.14.6

ConversionShaftToTool

Is an instance of

Function

L_TbCompare

Mark synchronisation (setpoint):

Comparison of the determined TP difference and the TP limit parameterised in

C03851 for the status message "TP limit exceeded" via C03875.



Mark synchronisation (setpoint) (C 39)

Parameter

Possible settings

Information

C03885

Comparison function

0 dnIn1 = dnIn2
1 dnIn1 > dnIn2

Lenze setting

2 dnIn1 < dnIn2
3 |dnIn1| = |dnIn2|
4 |dnIn1| > |dnIn2|
5 |dnIn1| < |dnIn2|

Is an instance of

Function

L_LdSyncOperation

Master value linking

Parameter

Possible settings

Information

C03715

Coupling of measuring systems X

and Y

0 Unit coupling
1 Cycle equality
2 Free coupling

Lenze setting

C03716/1

String of digits

User-defined unit X

• Read only

C03716/2

String of digits

User-defined unit Y

• Read only

C03717/1

0.0000

214748.3647 Coupling factor X

• Initialisation: 0.0000

C03717/2

0.0000

214748.3647 Coupling factor Y

• Initialisation: 0.0000

C03718/1

0

unit

2147483647 Cycle X

• Read only

C03718/2

0

unit

2147483647 Cycle Y

• Read only

C03719

-214748.3647

unit

214748.3647 Position X at the input

• Display of the dnXPosIn_p input

signal in the real unit of the

machine.

C03720

-214748.3647

unit

214748.3647 Trimming X

• Display of input signal

dnXOffset_p in real unit of the

machine.