5 comparetpdifftool, 6 conversionshafttotool – Lenze E94AxHE Technology Application Synchronism User Manual
Page 57
EDS94TA10040xxxx EN 1.1 - 10/2008
L
57
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Parameterisable function blocks
4.14.5
CompareTPDiffTool
4.14.6
ConversionShaftToTool
Is an instance of
Function
L_TbCompare
Mark synchronisation (setpoint):
Comparison of the determined TP difference and the TP limit parameterised in
C03851 for the status message "TP limit exceeded" via C03875.
Mark synchronisation (setpoint) (C 39)
Parameter
Possible settings
Information
C03885
Comparison function
0 dnIn1 = dnIn2
1 dnIn1 > dnIn2
Lenze setting
2 dnIn1 < dnIn2
3 |dnIn1| = |dnIn2|
4 |dnIn1| > |dnIn2|
5 |dnIn1| < |dnIn2|
Is an instance of
Function
L_LdSyncOperation
Master value linking
Parameter
Possible settings
Information
C03715
Coupling of measuring systems X
and Y
0 Unit coupling
1 Cycle equality
2 Free coupling
Lenze setting
C03716/1
String of digits
User-defined unit X
• Read only
C03716/2
String of digits
User-defined unit Y
• Read only
C03717/1
0.0000
214748.3647 Coupling factor X
• Initialisation: 0.0000
C03717/2
0.0000
214748.3647 Coupling factor Y
• Initialisation: 0.0000
C03718/1
0
unit
2147483647 Cycle X
• Read only
C03718/2
0
unit
2147483647 Cycle Y
• Read only
C03719
-214748.3647
unit
214748.3647 Position X at the input
• Display of the dnXPosIn_p input
signal in the real unit of the
machine.
C03720
-214748.3647
unit
214748.3647 Trimming X
• Display of input signal
dnXOffset_p in real unit of the
machine.